MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2014.02.051

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2014

Five-year real world outcomes of GeoForm ring implantation in patients with ischemic mitral regurgitation.

Timek Tomasz A, Hooker Robert L, Collingwood Robin, Davis Alan T, Alguire Craig T, Willekes Charles L, Murphy Edward T, Heiser John C, Patzelt Lawrence H

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Reductive ring annuloplasty represents the current standard surgical therapy for ischemic mitral regurgitation (IMR); however, the clinical results have been suboptimal. Etiology-specific prostheses such as the GeoForm annuloplasty ring have been designed to better address the annular and subvalvular perturbations associated with IMR. However, clinical experience is limited, and mid-term results are lacking.

METHODS

We reviewed the clinical outcomes of 86 patients who had undergone implantation of a GeoForm ring at our center from 2005 to 2011. Perioperative mortality and clinical parameters were derived from The Society of Thoracic Surgeons database. Follow-up survival was assessed using the Social Security Death Index. Surviving patients were interviewed by telephone for valve-specific follow-up data and to complete the Medical Outcomes Study, short-form, 36-item, quality-of-life questionnaire.

RESULTS

The mean grade of IMR preoperatively was 3.1±0.8 (range, 1-4+), 0.2±0.4 in the immediate postoperative period, and 0.7±0.7 at the last mean follow-up point of 41 months; only 2 patients developed ≥2+IMR during the follow-up period, for a 5-year freedom from recurrent 2+ IMR of 86%. The mean left ventricular end-diastolic and end-systolic diameters decreased from before to after surgery from 6.0±0.0 cm to 5.3±09 cm and 5.0±0.9 cm to 4.3±1.1 cm, respectively (P<.001). Perioperative mortality was 5.8% (5 of 86), and 1-, 3-, and 5-year survival was 87%, 81%, and 75%, respectively. At the last follow-up point, 80% of patients were in New York Heart Association class I and II, and their quality of life was equal to, or better than, age-matched controls from the general population.

CONCLUSIONS

Implantation of the GeoForm ring offers very good control of IMR, with low rate of recurrent IMR at mid-term follow-up. The use of this prosthesis was associated with good perioperative mortality, mid-term survival, and quality of life.

Для цитирования: Timek Tomasz A, Hooker Robert L, Collingwood Robin, Davis Alan T, Alguire Craig T, Willekes Charles L, Murphy Edward T, Heiser John C, Patzelt Lawrence H. Five-year real world outcomes of GeoForm ring implantation in patients with ischemic mitral regurgitation.. The Journal of thoracic and cardiovascular surgery. 2014. DOI: 10.1016/j.jtcvs.2014.02.051.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.