Left ventricular mass regression after sutureless implantation of the Perceval S aortic valve bioprosthesis: preliminary results.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Santarpino Giuseppe, Pfeiffer Steffen, Pollari Francesco, Concistrè Giovanni, Vogt Ferdinand, Fischlein Theodor
Аннотация
OBJECTIVES: Left ventricular (LV) hypertrophy in aortic stenosis (AS) is considered a compensatory response helping maintain systolic function, but constitutes a risk factor for cardiac morbidity and mortality. The aim of this study was to assess the degree of LV mass regression after sutureless implantation of the Perceval S aortic valve bioprosthesis (Sorin Group, Saluggia, Italy).
METHODS: Between March 2010 and July 2012, 78 patients with symptomatic AS underwent isolated aortic valve replacement (AVR) with the Perceval bioprosthesis. Mean age was 77.1 ± 5.3 years, 46 patients were female (59%) and mean logistic EuroSCORE was 11 ± 7.5%. Echocardiography was performed preoperatively, at discharge, and at follow-up (mean 13.5 ± 7.3 months). LV mass was calculated using the Devereux formula and indexed to body surface area.
RESULTS: There was 1 in-hospital non-cardiac death and 3 late deaths. LV mass index decreased from 148.4 ± 46 g/m(2) at baseline to 119.7 ± 38.5 g/m(2) at follow-up (P = 0.002). No significant changes were observed in LV hypertrophy and/or relative wall thickness >0.42 as well as in LV ejection fraction. Mean aortic gradient decreased from 49.5 ± 15.8 mmHg at baseline to 11.6 ± 5.1 mmHg at discharge and 8.3 ± 4.4 mmHg at follow-up (P < 0.001), resulting in significant clinical improvement. No moderate or severe paravalvular leakage was observed at discharge and at follow-up.
CONCLUSIONS: In AS patients, isolated AVR with the Perceval sutureless bioprosthesis is associated with significant LV mass regression at 1-year follow-up. However, longer-term follow-up is necessary to confirm these findings.
METHODS: Between March 2010 and July 2012, 78 patients with symptomatic AS underwent isolated aortic valve replacement (AVR) with the Perceval bioprosthesis. Mean age was 77.1 ± 5.3 years, 46 patients were female (59%) and mean logistic EuroSCORE was 11 ± 7.5%. Echocardiography was performed preoperatively, at discharge, and at follow-up (mean 13.5 ± 7.3 months). LV mass was calculated using the Devereux formula and indexed to body surface area.
RESULTS: There was 1 in-hospital non-cardiac death and 3 late deaths. LV mass index decreased from 148.4 ± 46 g/m(2) at baseline to 119.7 ± 38.5 g/m(2) at follow-up (P = 0.002). No significant changes were observed in LV hypertrophy and/or relative wall thickness >0.42 as well as in LV ejection fraction. Mean aortic gradient decreased from 49.5 ± 15.8 mmHg at baseline to 11.6 ± 5.1 mmHg at discharge and 8.3 ± 4.4 mmHg at follow-up (P < 0.001), resulting in significant clinical improvement. No moderate or severe paravalvular leakage was observed at discharge and at follow-up.
CONCLUSIONS: In AS patients, isolated AVR with the Perceval sutureless bioprosthesis is associated with significant LV mass regression at 1-year follow-up. However, longer-term follow-up is necessary to confirm these findings.
Предметные рубрики MeSH
AgedAged, 80 and overAortic ValveAortic Valve StenosisBioprosthesisEchocardiography, DopplerFemaleHeart Valve ProsthesisHeart Valve Prosthesis ImplantationHemodynamicsHospital MortalityHumansHypertrophy, Left VentricularMaleProsthesis DesignStroke VolumeTime FactorsTreatment OutcomeVentricular Function, LeftVentricular Remodeling