MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/icvts/ivt362

Медицинская библиотека · Interactive cardiovascular and thoracic surgery · 2013

Left ventricular mass regression after sutureless implantation of the Perceval S aortic valve bioprosthesis: preliminary results.

Santarpino Giuseppe, Pfeiffer Steffen, Pollari Francesco, Concistrè Giovanni, Vogt Ferdinand, Fischlein Theodor

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Left ventricular (LV) hypertrophy in aortic stenosis (AS) is considered a compensatory response helping maintain systolic function, but constitutes a risk factor for cardiac morbidity and mortality. The aim of this study was to assess the degree of LV mass regression after sutureless implantation of the Perceval S aortic valve bioprosthesis (Sorin Group, Saluggia, Italy).

METHODS

Between March 2010 and July 2012, 78 patients with symptomatic AS underwent isolated aortic valve replacement (AVR) with the Perceval bioprosthesis. Mean age was 77.1 ± 5.3 years, 46 patients were female (59%) and mean logistic EuroSCORE was 11 ± 7.5%. Echocardiography was performed preoperatively, at discharge, and at follow-up (mean 13.5 ± 7.3 months). LV mass was calculated using the Devereux formula and indexed to body surface area.

RESULTS

There was 1 in-hospital non-cardiac death and 3 late deaths. LV mass index decreased from 148.4 ± 46 g/m(2) at baseline to 119.7 ± 38.5 g/m(2) at follow-up (P = 0.002). No significant changes were observed in LV hypertrophy and/or relative wall thickness >0.42 as well as in LV ejection fraction. Mean aortic gradient decreased from 49.5 ± 15.8 mmHg at baseline to 11.6 ± 5.1 mmHg at discharge and 8.3 ± 4.4 mmHg at follow-up (P < 0.001), resulting in significant clinical improvement. No moderate or severe paravalvular leakage was observed at discharge and at follow-up.

CONCLUSIONS

In AS patients, isolated AVR with the Perceval sutureless bioprosthesis is associated with significant LV mass regression at 1-year follow-up. However, longer-term follow-up is necessary to confirm these findings.

Для цитирования: Santarpino Giuseppe, Pfeiffer Steffen, Pollari Francesco, Concistrè Giovanni, Vogt Ferdinand, Fischlein Theodor. Left ventricular mass regression after sutureless implantation of the Perceval S aortic valve bioprosthesis: preliminary results.. Interactive cardiovascular and thoracic surgery. 2013. DOI: 10.1093/icvts/ivt362.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.