MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4244/eijv9i8a156

Медицинская библиотека · EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2013

Impact of low-profile sheaths on vascular complications during transfemoral transcatheter aortic valve replacement.

Barbanti Marco, Binder Ronald K, Freeman Melanie, Wood David A, Leipsic Jonathon, Cheung Anson, Ye Jian, Tan John, Toggweiler Stefan, Yang Tae-Hyun, Dvir Danny, Maryniak Kasia, Lauck Sandra, Webb John G

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: We sought to assess the impact of low-profile sheaths on vascular complications during transfemoral transcatheter aortic valve replacement (TAVR).

METHODS AND

RESULTS

This retrospective single-study population comprised a total of 375 consecutive patients with severe aortic stenosis who underwent transfemoral TAVR from January 2008 to November 2012. Of these, 204 (54.4%) underwent TAVR using 14-18 Fr sheaths (low-profile sheath [LPS] group), and 171 (45.6%) using 19-24 Fr sheaths (high-profile sheath [HPS] group). Vascular complications and bleeding were defined according to the VARC-2 definitions. Lower-profile sheaths were associated with a lower incidence of major vascular complications (0.5% vs. 10.5%, p<0.001), as well as a lower rate of life-threatening or major bleeding (3.4% vs. 8.3%, p=0.038). Finally, at multivariable analysis, sheath size ≥19 Fr (adjusted odds ratio [OR]: 3.06, 95% confidence interval [CI]: 1.20-7.83; p=0.019) and a sheath external diameter/minimal femoral artery diameter ratio ≥1.05 (adjusted OR: 5.79, 95% CI: 1.29-15.92, p=0.022) were found to be the only independent predictors of major and minor vascular complications.

CONCLUSIONS

The introduction of lower-profile sheaths has dramatically reduced the incidence of vascular complications after transfemoral TAVR, thus enhancing the safety of the procedure.

Для цитирования: Barbanti Marco, Binder Ronald K, Freeman Melanie, Wood David A, Leipsic Jonathon, Cheung Anson, Ye Jian, Tan John, Toggweiler Stefan, Yang Tae-Hyun, Dvir Danny, Maryniak Kasia, Lauck Sandra, Webb John G. Impact of low-profile sheaths on vascular complications during transfemoral transcatheter aortic valve replacement.. EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. 2013. DOI: 10.4244/eijv9i8a156.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.