Heart rhythm · 2013
Long-term ECG monitoring using an implantable loop recorder for the detection of atrial fibrillation after cavotricuspid isthmus ablation in patients with atrial flutter.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Mittal Suneet, Pokushalov Evgeny, Romanov Alexander, Ferrara Martha, Arshad Aysha, Musat Dan, Preminger Mark, Sichrovsky Tina, Steinberg Jonathan S
Аннотация
BACKGROUND: In patients with atrial flutter who undergo cavotricuspid isthmus ablation, long-term electrocardiographic (ECG) monitoring may identify new onset of atrial fibrillation (AF).
OBJECTIVES: To ascertain, through the use of an implantable loop recorder (ILR) with a dedicated AF detection algorithm, the incidence, duration, and burden of new AF in these patients and to develop an optimal postablation ECG monitoring strategy.
METHODS: We enrolled 20 patients with flutter, a CHADS2 score of 2-3, and no prior episode of AF. After cavotricuspid isthmus ablation, we implanted an ILR, which was interrogated routinely; all stored ECGs were adjudicated.
RESULTS: During a mean follow-up of 382 ± 218 days, 3 patterns were observed. First, in 11 (55%) patients, stored ECGs confirmed AF at 62 ± 38 days after ablation. Second, in 4 (20%) patients, although the ILR suggested AF, episodes actually represented sinus rhythm with frequent premature atrial contractions and/or oversensing. Third, in 5 (25%) patients, no AF was observed. Episodes <4 hours were associated with low AF burden (<1%) or false detections. The 1-year freedom from any episode of AF >4 and >12 hours was 52% and 83%, respectively.
CONCLUSIONS: Our data show that many (but not all) patients develop new AF within the first 4 months of flutter ablation. Since external ECG monitoring for this duration is impractical, the ILR has an important role for long-term AF surveillance. Future research should be directed toward identifying the relationship between duration/burden of AF and stroke and improving existing ILR technology.
OBJECTIVES: To ascertain, through the use of an implantable loop recorder (ILR) with a dedicated AF detection algorithm, the incidence, duration, and burden of new AF in these patients and to develop an optimal postablation ECG monitoring strategy.
METHODS: We enrolled 20 patients with flutter, a CHADS2 score of 2-3, and no prior episode of AF. After cavotricuspid isthmus ablation, we implanted an ILR, which was interrogated routinely; all stored ECGs were adjudicated.
RESULTS: During a mean follow-up of 382 ± 218 days, 3 patterns were observed. First, in 11 (55%) patients, stored ECGs confirmed AF at 62 ± 38 days after ablation. Second, in 4 (20%) patients, although the ILR suggested AF, episodes actually represented sinus rhythm with frequent premature atrial contractions and/or oversensing. Third, in 5 (25%) patients, no AF was observed. Episodes <4 hours were associated with low AF burden (<1%) or false detections. The 1-year freedom from any episode of AF >4 and >12 hours was 52% and 83%, respectively.
CONCLUSIONS: Our data show that many (but not all) patients develop new AF within the first 4 months of flutter ablation. Since external ECG monitoring for this duration is impractical, the ILR has an important role for long-term AF surveillance. Future research should be directed toward identifying the relationship between duration/burden of AF and stroke and improving existing ILR technology.