Long-term ECG monitoring using an implantable loop recorder for the detection of atrial fibrillation after cavotricuspid isthmus ablation in patients with atrial flutter.

Mittal Suneet, Pokushalov Evgeny, Romanov Alexander, Ferrara Martha, Arshad Aysha, Musat Dan, Preminger Mark, Sichrovsky Tina, Steinberg Jonathan S

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

In patients with atrial flutter who undergo cavotricuspid isthmus ablation, long-term electrocardiographic (ECG) monitoring may identify new onset of atrial fibrillation (AF).

OBJECTIVES

To ascertain, through the use of an implantable loop recorder (ILR) with a dedicated AF detection algorithm, the incidence, duration, and burden of new AF in these patients and to develop an optimal postablation ECG monitoring strategy.

METHODS

We enrolled 20 patients with flutter, a CHADS2 score of 2-3, and no prior episode of AF. After cavotricuspid isthmus ablation, we implanted an ILR, which was interrogated routinely; all stored ECGs were adjudicated.

RESULTS

During a mean follow-up of 382 ± 218 days, 3 patterns were observed. First, in 11 (55%) patients, stored ECGs confirmed AF at 62 ± 38 days after ablation. Second, in 4 (20%) patients, although the ILR suggested AF, episodes actually represented sinus rhythm with frequent premature atrial contractions and/or oversensing. Third, in 5 (25%) patients, no AF was observed. Episodes <4 hours were associated with low AF burden (<1%) or false detections. The 1-year freedom from any episode of AF >4 and >12 hours was 52% and 83%, respectively.

CONCLUSIONS

Our data show that many (but not all) patients develop new AF within the first 4 months of flutter ablation. Since external ECG monitoring for this duration is impractical, the ILR has an important role for long-term AF surveillance. Future research should be directed toward identifying the relationship between duration/burden of AF and stroke and improving existing ILR technology.

Для цитирования: Mittal Suneet, Pokushalov Evgeny, Romanov Alexander, Ferrara Martha, Arshad Aysha, Musat Dan, Preminger Mark, Sichrovsky Tina, Steinberg Jonathan S. Long-term ECG monitoring using an implantable loop recorder for the detection of atrial fibrillation after cavotricuspid isthmus ablation in patients with atrial flutter.. Heart rhythm. 2013. DOI: 10.1016/j.hrthm.2013.07.044.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.