MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cmpb.2020.105416

Медицинская библиотека · Computer methods and programs in biomedicine · 2020

Glucose outcomes of a learning-type artificial pancreas with an unannounced meal in type 1 diabetes.

Song Lulu, Liu Changqing, Yang Wenying, Zhang Jinping, Kong Xiaomu, Zhang Bo, Chen Xiaoping, Wang Na, Shen Dong, Li Zhaoqing, Jin Xian, Shuai Ying, Wang Youqing

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVES

Glycemic control with unannounced meals is the major challenge for artificial pancreas. In this study, we described the performance and safety of learning-type model predictive control (L-MPC) for artificial pancreas challenged by an unannounced meal in type 1 diabetes (T1D).

METHODS

This closed-loop (CL) system was tested in 29 T1D patients at one site in a 4 h inpatient open-label study. Participants used an L-MPC CL system for 6 days after 2-day system identification using open-loop (OL) insulin system. During the CL period, the L-MPC system was started from 8:00 am to noon each day. At 9:00 am, each participant consumed 50 g of carbohydrates with no prandial insulin bolus. At 9:30 am on CL-Day 4 or CL-Day 6, participants rode bicycles for 20 minutes or drank 50 ml of beer, in a random order.

RESULTS

As the primary outcome, TIR on CL-Day 3 was 65.2±23.3%, which was 9.8 points higher (95% CI 1.8 to 17.8; P = 0.019) than that on CL-Day 1. The time of glucose >10 mmol/L was decreased by 11.0% (95% CI -18.7 to 3.3; P = 0.007), and mean glucose level was decreased by 1.1 mmol/L (95% CI -1.1 to 0.5; P = 0.000). The total daily insulin dosage showed no significant difference (-0.1U, 95% CI -1.34 to 1.32; P = 0.982). Compared with OL-Day1 with a postprandial bolus, the TIR was increased by 13.7 points (95% CI 1.4 to 26.0; P = 0.030), the time of glucose >10 mmol/L and the mean glucose level were also decreased. Compared with the exercise day (CL-Day E, 62.0 ± 23.3%; P = 0.347) or alcohol day (CL-Day A, 64.0 ± 23.6%; P = 0.756), there was no statistically significant difference in terms of TIR, time of glucose >10 mmol/L and mean glucose level. No severe hypoglycemic events occurred and hypoglycemic episodes were not increased by using closed-loop insulin system.

CONCLUSION

The L-MPC CL insulin system achieved good glycemic control challenged by an unannounced meal.

Для цитирования: Song Lulu, Liu Changqing, Yang Wenying, Zhang Jinping, Kong Xiaomu, Zhang Bo, Chen Xiaoping, Wang Na, Shen Dong, Li Zhaoqing, Jin Xian, Shuai Ying, Wang Youqing. Glucose outcomes of a learning-type artificial pancreas with an unannounced meal in type 1 diabetes.. Computer methods and programs in biomedicine. 2020. DOI: 10.1016/j.cmpb.2020.105416.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.