MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/hed.21228

Медицинская библиотека · Head & neck · 2010

Benefit of measuring basal serum calcitonin to detect medullary thyroid carcinoma in a Danish population with a high prevalence of thyroid nodules.

Hasselgren Martin, Hegedüs Laszlo, Godballe Christian, Bonnema Steen Joop

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Routine measurement of serum calcitonin to detect medullary thyroid carcinoma (MTC) continues to be fiercely debated, although less attention has been paid to the positive predictive value (PPV) of this method.

METHODS

We collected data from 959 patients with nontoxic nodular goiter; thyroidectomy was performed in 307 of these patients.

RESULTS

Thirty-nine patients had elevated serum calcitonin; 6 of these patients had MTC detected by the initial diagnostic setup. No additional patient in the cohort was registered in the Danish Thyroid Cancer Database, reflecting that all patients with MTC were classified correctly initially. The sensitivity of serum calcitonin for detection of MTC was 100%, the specificity was 95.3%, the positive predictive value was 15.4%, and the negative predictive value was 100%.

CONCLUSION

Serum calcitonin has high sensitivity and specificity for detection of MTC. The low PPV might lead to unnecessary thyroid surgery. Thus, the result of serum calcitonin measurement should always be interpreted in the context of other clinical variables.

Для цитирования: Hasselgren Martin, Hegedüs Laszlo, Godballe Christian, Bonnema Steen Joop. Benefit of measuring basal serum calcitonin to detect medullary thyroid carcinoma in a Danish population with a high prevalence of thyroid nodules.. Head & neck. 2010. DOI: 10.1002/hed.21228.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.