m+Medelevator.RU
← Поиск публикаций
Journal of cardiovascular electrophysiology · 2024

Association between high-density mapping of atypical atrial flutter, clinical outcomes and healthcare utilization.

СтатьяСравнительное исследованиеПоддержка NIH: внешняя программаПоддержка правительства СШАПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sink Joshua, Culler Kasen, Uppalapati Lakshmi, Lancki Nicola, Peigh Graham, Lohrmann Graham, Elsayed Mahmoud, Carneiro Herman, Baman Jayson, Pfenniger Anna, Patil Kaustubha D, Verma Nishant, Arora Rishi, Kim Susan S, Chicos Alexandru B, Lin Albert C, Knight Bradley P, Passman Rod S

Аннотация

BACKGROUND: Success of atypical atrial flutter (AAFL) ablation has historically been limited by difficulty mapping the complex re-entrant circuits involved. While high-density (HD) mapping has become commonplace in clinical practice, there are limited data on outcomes of HD versus non-HD mapping for AAFL ablation.

OBJECTIVE: To compare clinical outcomes and healthcare utilization using HD mapping versus non-HD mapping for AAFL ablation.

METHODS: Retrospective analysis of all AAFL procedures between 2005 and 2022 at an academic medical center was conducted. Procedures utilizing a 16-electrode HD Grid catheter and Precision mapping system were compared to procedures using prior generation 10-20 electrode spiral catheters and the Velocity system (Abbott, IL). Cox regression models and Poisson regression models were utilized to examine procedural and healthcare utilization outcomes. Models were adjusted for left ventricular ejection fraction, CHA2DS2-VASc, and history of prior ablation.

RESULTS: There were 108 patients (62% HD mapping) included in the analysis. Baseline clinical characteristics were similar between groups. Use of HD mapping was associated with a higher rate of AAFL circuit delineation (92.5% vs. 76%; p = .014) and a greater adjusted procedure success rate, defined as non-inducibility at procedure end, (aRR (95% CI) 1.26 (1.02-1.55) p = .035) than non-HD mapping. HD mapping was also associated with a lower rate of ED visits (aIRR (95% CI) 0.32 (0.14-0.71); p = .007) and hospitalizations (aIRR (95% CI) 0.32 (0.14-0.68); p = .004) for AF/AFL/HF through 1 year. While there was a lower rate of recurrent AFL through 1 year among HD mapping cases (aHR (95% CI) 0.60 (0.31-1.16) p = .13), statistical significance was not met likely due to the low sample size and higher rate of ambulatory rhythm monitoring in the HD group (61% vs. 39%, p = .025).

CONCLUSION: Compared to non-HD mapping, AAFL ablation with HD mapping is associated with improvements in the ability to define the AAFL circuit, greater procedural success, and a reduction in the number of ED visits and hospitalization for AF/AFL/HF.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты