Cancer · 2008
Thin core needle biopsy crush preparations in conjunction with fine-needle aspiration for the evaluation of thyroid nodules: a complementary approach.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Zhang Songlin, Ivanovic Marina, Nemcek Albert A, Defrias Denise V S, Lucas Erin, Nayar Ritu
Аннотация
BACKGROUND: Fine-needle aspiration (FNA) is widely accepted as the initial test to evaluate thyroid nodules; however, inadequate and suboptimal specimens have been 1 of its limitations. Unsatisfactory rates of 4.1% to 43% have been reported, but suboptimal specimens with adequate epithelial cells and other limiting factors, such as clotting, often are not addressed. The authors' institution has a low unsatisfactory rate, especially for thyroid biopsies performed under ultrasound in the Interventional Radiology (IR) Department. In addition to on-site evaluation for all cases, they concomitantly use thin, 22/20-gauge core needle biopsy (CB) crush preparations (CP) for unsatisfactory/suboptimal FNAs. The CB usually is done after 2 FNA passes and, in most cases, is exhausted by making an air-dried CP, which is evaluated on site for adequacy; any residual tissue is processed for tissue sections. Experience is required to interpret CP on air-dried smears. In this report, the authors describe a complementary approach to thyroid biopsy that has worked well.
METHODS: All thyroid FNA and CB/CP that were performed in the IR Department during the year 2005 were reviewed. Follow-up histology and records of all procedural complications were retrieved.
RESULTS: Seven hundred thirteen thyroid biopsies qualified, 225 biopsies (31%) had FNA with CB/CP (85% had only CP for evaluation), and 488 biopsies (69%) had only FNA. The final unsatisfactory rate in IR for FNA was 8.7%; this was reduced to 3.4% with the use of CB/CP. The addition of CB also helped to obtain a more definitive diagnosis in suboptimal FNA specimens. Cytologic-histologic correlation was comparable for FNA only cases and FNA/CB cases. There were no significant procedural complications in CB cases.
CONCLUSIONS: FNA in conjunction with a thin CB/CP performed during the same procedure is a safe technique that can reduce the rate of unsatisfactory and suboptimal thyroid biopsy.
METHODS: All thyroid FNA and CB/CP that were performed in the IR Department during the year 2005 were reviewed. Follow-up histology and records of all procedural complications were retrieved.
RESULTS: Seven hundred thirteen thyroid biopsies qualified, 225 biopsies (31%) had FNA with CB/CP (85% had only CP for evaluation), and 488 biopsies (69%) had only FNA. The final unsatisfactory rate in IR for FNA was 8.7%; this was reduced to 3.4% with the use of CB/CP. The addition of CB also helped to obtain a more definitive diagnosis in suboptimal FNA specimens. Cytologic-histologic correlation was comparable for FNA only cases and FNA/CB cases. There were no significant procedural complications in CB cases.
CONCLUSIONS: FNA in conjunction with a thin CB/CP performed during the same procedure is a safe technique that can reduce the rate of unsatisfactory and suboptimal thyroid biopsy.