The Biplane Modified Simpson's Method Accurately Estimates Pericardial Effusion Volume: A Comparison with Pericardiocentesis.

Khosraviani Khashayar, Goldberg Ythan, Salari Behzad, Nezami Nariman, Peng Chang-Fu, Taub Cynthia C

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Pericardial effusion (PE) volume is often assessed semiqualitatively by echocardiography and categorized into minimal, small, moderate, or large. Several methods of echocardiographic quantification have been proposed, but their application is limited either by complexity or inaccuracy. We evaluated the accuracy of PE volume quantification by two-dimensional transthoracic echocardiogram (2DTTE) and commercially available volume quantification software in patients undergoing pericardiocentesis.

METHODS

In a retrospective case series, immediate preprocedure echocardiograms of 33 patients for pericardiocentesis were analyzed. 2DTTE using the Simpson's method was adopted for volume measurement in the apical two- and four-chamber views. Pericardial fluid volume was calculated by taking the difference between volumes obtained by tracing the epicardial border of the heart and the pericardium. Postprocedure echocardiograms were performed to verify adequate pericardiocentesis.

RESULTS

The mean pericardiocentesis fluid volume was 725.1 ± 299.5 mL (range, 250-1420 mL). The average volume estimated echocardiographically by the Simpson's method was 657.5 ± 276.9 mL (range, 205.7-1193.2 mL). There was strong direct linear correlation between echocardiographic and pericardiocentesis-derived volumes (P < 0.001, r = +0.823). Echocardiography underestimated PE volume by a mean of 9.3%.

CONCLUSION

Two-dimensional transthoracic echocardiography using biplane Simpson's method of disks can simply and accurately estimate PE volume.

Для цитирования: Khosraviani Khashayar, Goldberg Ythan, Salari Behzad, Nezami Nariman, Peng Chang-Fu, Taub Cynthia C. The Biplane Modified Simpson's Method Accurately Estimates Pericardial Effusion Volume: A Comparison with Pericardiocentesis.. Echocardiography (Mount Kisco, N.Y.). 2014. DOI: 10.1111/echo.12833.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.