DOI 10.1016/j.hrthm.2014.10.013
Clinical utility of routine use of continuous transesophageal echocardiography monitoring during transvenous lead extraction procedure.
Аннотация
BACKGROUND
Data on the use of transesophageal echocardiography (TEE) during transvenous lead extraction (TLE) procedures are scarce.
OBJECTIVE
The purpose of this study was to assess the routine use of TEE during transvenous lead extraction.
METHODS
From January 2009 to January 2014, TLE of 241 leads in 168 patients (mean age 70 ± 13 years, 129 male, left ventricular ejection fraction 37% ± 13%) was performed. Indication for TLE was lead dysfunction (56.5%), upgrade (27.0%), infection (13%), or other (3.1%). TLE techniques combined a mechanical approach amended by laser technique if required. Extraction procedures were performed with patients under general anesthesia with continuous invasive arterial blood pressure and TEE monitoring.
RESULTS
TEE was possible in all except 1 patient. TEE images in different projections were acquired and stored before and immediately after extraction of each lead. TLE was complete for 236 of 241 leads (97.9%); 4 distal lead tips (1.7%) remained in situ, and 1 dual-coil implantable cardioverter-defibrillator electrode (0.4%) could not be removed. New TEE findings after TLE were observed in 7 of 161 cases (4.3%): pericardial effusion (mild in 4 [2.5%] and severe in 1 [0.6%]) and worsening of tricuspid valve insufficiency (2 patients [1.2%]). The only case of severe pericardial effusion occurred after laceration of the superior vena cava, which required immediate rescue surgery (0.6%, confidence interval 0.01-3.3). In all other cases, TEE findings did not entail immediate diagnostic or therapeutic measures.
CONCLUSION
New TEE findings produced during TLE necessitating immediate therapeutic measures occurred in only 0.6% of cases, suggesting the limited utility of routine continuous TEE monitoring during TLE.