MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2014.09.010

Медицинская библиотека · Heart rhythm · 2014

Left atrial appendage electrical isolation and concomitant device occlusion: A safety and feasibility study with histologic characterization.

Panikker Sandeep, Virmani Renu, Sakakura Kenichi, Kolodgie Frank, Francis Darrel P, Markides Vias, Walcott Greg, McElderry H Tom, Wong Tom

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Left atrial appendage (LAA) electrical isolation is reported to improve atrial fibrillation ablation outcomes. However, loss of mechanical function may increase thromboembolic risk.

OBJECTIVE

The aim of this study was to evaluate the feasibility and safety of LAA occlusion after electrical isolation in a canine model.

METHODS

Nine canines underwent LAA isolation with irrigated radiofrequency ablation after pulmonary vein (PV) isolation. Entrance and exit block were confirmed with intravenous adenosine after 30 minutes. The LAA was then occluded with a Watchman device. Device position was assessed at 10 days by using transthoracic echocardiography. At 45 days, LAA isolation was assessed epicardially. Hearts were then examined macroscopically and histologically.

RESULTS

All 36 PVs and 8 of 9 LAAs (89%) were electrically isolated. Acute LAA reconnection occurred in 4 of 8 LAAs (50%). All were reisolated. The mean ablation time was 51 ± 19 minutes, including 24 ± 18 minutes for LAA isolation. LAA occlusion was successful in all cases. One animal died of a primary intracranial bleed due to anticoagulant hypersensitivity 36 hours after the procedure. Transthoracic echocardiography at 10 days confirmed satisfactory device positions and no pericardial effusion. At 45 days, 7 of 8 (88%) had persistent LAA electrical isolation. All devices were stable without evidence of erosion. Microscopy revealed complete device-tissue apposition and a mature connective tissue layer overlying the device surface in all cases.

CONCLUSION

LAA electrical isolation and mechanical occlusion can be performed concomitantly in this animal model, with no displacement or mechanical erosion of the appendage at 45 days. This technique can potentially improve success rates and obviate the need for chronic anticoagulation. Future studies should address efficacy, safety, and feasibility in humans.

Для цитирования: Panikker Sandeep, Virmani Renu, Sakakura Kenichi, Kolodgie Frank, Francis Darrel P, Markides Vias, Walcott Greg, McElderry H Tom, Wong Tom. Left atrial appendage electrical isolation and concomitant device occlusion: A safety and feasibility study with histologic characterization.. Heart rhythm. 2014. DOI: 10.1016/j.hrthm.2014.09.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.