MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/cod.13870

Медицинская библиотека · Contact dermatitis · 2021

Patch testing with aluminium Finn Chambers could give false-positive reactions in patients with contact allergy to aluminium.

Rosholm Comstedt Lisbeth, Dahlin Jakob, Bruze Magnus, Hedberg Yolanda, Matura Mihály, Svedman Cecilia

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Earlier laboratory studies have shown that sodium tetrachloropalladate, Myroxylon pereirae, caine mix II, and palladium chloride trigger the release of aluminium (Al) from Finn Chambers (FC).

OBJECTIVES

To investigate whether aluminium realease from FC could influence the diagnostic outcome of patch testing with FC.

METHOD: A retrospective analysis of patch test results from 2010 to 2019 was performed. A two-sided Fisher's exact test was used to calculate any overrepresentation of contact allergy to Al among patients with positive reactions to sodium tetrachloropalladate, Myroxylon pereirae, caine mix II, and palladium chloride.

RESULTS

A total of 5446 patients had been tested with FC during the study period. There was a significant overrepresentation of contact allergy to Al among patients with positive reactions to sodium tetrachloropalladate, Myroxylon pereirae, caine mix II, and palladium chloride. Patients with a strong Al allergy had significantly higher amounts of concomitant reactions to sodium tetrachloropalladate, Myroxylon pereirae, caine mix II, and palladium chloride compared to patients with weak Al allergy. These results were not seen for patients tested with Finn Chambers AQUA.

CONCLUSION

In patients with contact allergy to Al, patch testing with Finn chambers could give false-positive reactions to sodium tetrachloropalladate, Myroxylon pereirae, caine mix II, and palladium chloride.

Для цитирования: Rosholm Comstedt Lisbeth, Dahlin Jakob, Bruze Magnus, Hedberg Yolanda, Matura Mihály, Svedman Cecilia. Patch testing with aluminium Finn Chambers could give false-positive reactions in patients with contact allergy to aluminium.. Contact dermatitis. 2021. DOI: 10.1111/cod.13870.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.