MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1540-8159.2007.00927.x

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2008

Electrical remodeling and cardiac dimensions in patients treated by cardiac resynchronization and heart failure controls.

Stockburger Martin, Nitardy Aischa, Fateh-Moghadam Suzanne, Krebs Alice, Celebi Ozlem, Karhausen Tim, Dietz Rainer

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Cardiac resynchronization therapy (CRT) reduces the left ventricular diameter (LVEDD) in heart failure (HF) patients with left bundle branch block (LBBB). The study compares structural and electrical remodeling in HF patients on CRT and matched HF controls without LBBB.

METHODS

In 42 patients (64 +/- 9 years left ventricular ejection fraction [LVEF] 25 +/- 8%, 16 coronary artery disease, 26 nonischemic cardiomyopathy, 21 with LBBB and CRT indication vs 21 controls [matched for gender, age, LVEF, and underlying disease]) an unpaced electrocardiogram (ECG) and echocardiogram were recorded at baseline (bl) and after 20.6 +/- 13.8 months (fup). LVEDD, left atrial (LA) width, mitral regurgitation (MR), P-wave, PR interval, QRS width, QRS vector, and QT interval were analyzed.

RESULTS

LVEDD diminished with CRT (bl 68.7 +/- 10.3 vs fup 62.0 +/- 7.7 mm, P = 0.002). Controls showed no change (bl 64.1 +/- 9.4 vs fup 64.8 +/- 8.4 mm, P = n.s.). MR improved with CRT (bl 1.2 +/- 0.6 vs fup 0.8 +/- 0.7, P = 0.02), but not among controls. LA width tended to decrease on CRT (CRT bl 48.9 +/- 4.4 vs fup 46.9 +/- 7.2 mm, P = 0.17, controls bl 48.5 +/- 5.1 vs fup 47.5 +/- 6.5 mm, P = 0.49). PR interval lengthened in both groups (CRT bl 175 +/- 29 vs fup 188 +/- 30 ms, P = 0.03, controls bl 177+/-25 vs fup 187 +/- 19 ms, P = 0.27). QRS increased in both groups (CRT bl 165 +/- 22 vs fup 171 +/- 20 ms, P = 0.07, controls bl 111 +/- 17 vs fup 118 +/- 19 ms, P = 0.01). Analyses revealed no significant association of echocardiographic and ECG parameters.

CONCLUSIONS

Despite LVEDD reduction with CRT, electrical activation does not recover. Electrical remodeling does not differ between LBBB patients under CRT and matched controls without CRT indication.

Для цитирования: Stockburger Martin, Nitardy Aischa, Fateh-Moghadam Suzanne, Krebs Alice, Celebi Ozlem, Karhausen Tim, Dietz Rainer. Electrical remodeling and cardiac dimensions in patients treated by cardiac resynchronization and heart failure controls.. Pacing and clinical electrophysiology : PACE. 2008. DOI: 10.1111/j.1540-8159.2007.00927.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.