BACKGROUND

The electrocardiogram (ECG) patterns during pacing from the great cardiac vein (GCV) and the middle cardiac vein (MCV) are not well known.

METHODS

We recorded 12-lead ECGs during GCV and MCV pacing in 26 patients undergoing implantation of a cardiac resynchronization device. The left ventricular (LV) lead was passed down the GCV (n = 19) or MCV (n = 7) prior to moving it to a lateral or posterolateral vein for permanent implantation.

RESULTS AND

CONCLUSIONS

Pacing within the GCV resulted in a left bundle branch block (LBBB) morphology with no or minimal R-wave in V(1) in 14 patients and a right bundle branch block (RBBB) pattern (R > S in lead V(1)) in four patients. In one patient, lead V1 during GCV pacing was isoelectric (R = S). A more distal pacing site in the GCV yielded a LBBB pattern in all the patients. All leads placed in the MCV resulted in a LBBB configuration. An ECG pattern with a RBBB pattern was invariably recorded during LV pacing in 125 consecutive outpatients with biventricular pacemakers and LV leads in the posterolatral and lateral coronary veins. Knowledge of the ECG patterns from various pacing sites in the coronary venous system may be helpful for troubleshooting all types of pacing systems, especially those where the coronary venous pacing site is unintentional.

Для цитирования: Giudici Michael C, Tigrett Darryn W, Carlson Jacqueline I, Lorenz Terri D, Paul Deborah L, Barold S Serge. Electrocardiographic patterns during: pacing the great cardiac and middle cardiac veins.. Pacing and clinical electrophysiology : PACE. 2007. DOI: 10.1111/j.1540-8159.2007.00874.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.