m+Medelevator.RU
← Поиск публикаций
Heart rhythm · 2007

Changes and predictive value of dispersion of repolarization parameters for appropriate therapy in patients with biventricular implantable cardioverter-defibrillators.

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lellouche Nicolas, De Diego Carlos, Akopyan Gina, Boyle Noel G, Mahajan Aman, Cesario David A, Wiener Isaac, Shivkumar Kalyanam

Аннотация

BACKGROUND: The impact of cardiac resynchronization therapy (CRT) on dispersion of repolarization is controversial. The benefit of CRT on sudden cardiac death has been demonstrated only after 3 years follow-up.

OBJECTIVE: The purpose of this study was to explore the immediate effect of CRT on dispersion of repolarization and to define the value of dispersion of repolarization parameters as predictors of appropriate implantable cardioverter-defibrillator (ICD) therapy.

METHODS: Data from 100 patients who underwent CRT-ICD placement were analyzed retrospectively. Patients had symptoms of New York Heart Association functional class III or IV heart failure, left ventricular ejection fraction < or =35%, and QRS duration >130 ms or QRS < or =130 ms with left intraventricular dyssynchrony. ECG indices of dispersion of repolarization before and immediately after CRT implantation (QT dispersion, Tpeak-Tend [Tp-e], and Tp-e dispersion) were measured.

RESULTS: In patients who were upgraded to a biventricular system, Tp-e did not increase significantly after CRT. However, Tp-e increased significantly after CRT in patients with left bundle branch block or narrow QRS at baseline. After 12-month follow-up, 22 patients had received appropriate ICD therapy. ICD therapy and no ICD therapy groups had similar baseline characteristics, such as secondary prevention and ischemic cardiomyopathy. Postimplantation Tp-e was the only independent predictor of future ICD therapy (P = .02).

CONCLUSION: Immediately after CRT, Tp-e did not increase in patients who received a biventricular upgrade; however, Tp-e did increase in patients with preimplantation left bundle branch block or narrow QRS. Postimplantation Tp-e was the only independent predictor of appropriate ICD therapy.