MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Anadolu kardiyoloji dergisi : AKD = the Anatolian journal of cardiology · 2007

Twenty-millisecond interventricular difference as assessed by body surface potential mapping identifies patients with clinical improvement after implantation of cardiac resynchronization device.

Samesima Nelson, Douglas Roberto, Tobias Nancy, Pedrosa Anísio, Martinelli Filho Martino, Ramires José Antonio, Pastore Carlos Alberto

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

There is little research on the ventricular electrical aspects following cardiac resynchronization therapy (CRT). This study sought to establish electrocardiographic criteria associated to the ventricular electrical activation process that could identify patients with functional class (FC) improvement after CRT, by using the noninvasive method of body surface potential mapping (BSPM).

METHODS

Fifty-six patients with chronic heart failure and left bundle-branch block (LBBB), who had undergone CRT, with mean age 59.9+/-10.8 years, left ventricular ejection fraction 30.9+/-8.3%, QRS 184+/-35 ms, FC (NYHA) II - 16%, III - 68% and IV - 16%, were selected. Through the 87-lead BSPM isochronous maps, ventricular activation times (VAT) of both right (RV) and left ventricles (LV) were analysed, in two situations: (1) native LBBB and (2) during biventricular pacing. After CRT, patients were divided in two groups: with and without FC improvement. The VATs were compared by the Mann-Whitney's test. The ratio of patients with and without FC improvement who showed RV-to-LV VAT difference =or<20 ms, and >20 ms, was compared using the Fisher's test. Significance level was accepted as p=or<0.05.

RESULTS

Clinical characteristics of patients before CRT were similar in the groups. Patients with FC improvement (47) had RV-to-LV VAT difference during biventricular pacing shorter than those without FC improvement (14.40+/-13.0 ms vs 23.8+/-9.4 ms, p=0.0151). Moreover, the majority of patients with FC improvement had an RV-to-LV VAT difference =or<20 ms during biventricular pacing (70% vs 22%, RR 5.8, CI 95% 1.334-25.517, p=0.01).

CONCLUSION

The RV-to-LV ventricular activation time difference of less than or equal to 20 milliseconds, as characterised by BSPM, could identify patients who presented with improved functional class after undergoing CRT.

Для цитирования: Samesima Nelson, Douglas Roberto, Tobias Nancy, Pedrosa Anísio, Martinelli Filho Martino, Ramires José Antonio, Pastore Carlos Alberto. Twenty-millisecond interventricular difference as assessed by body surface potential mapping identifies patients with clinical improvement after implantation of cardiac resynchronization device.. Anadolu kardiyoloji dergisi : AKD = the Anatolian journal of cardiology. 2007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.