MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/mrm.21142

Медицинская библиотека · Magnetic resonance in medicine · 2007

Quantitative comparison of 2D and 3D circumferential strain using MRI tagging in normal and LBBB hearts.

Tecelão Sandra R R, Zwanenburg Jaco J M, Kuijer Joost P A, de Cock Carel C, Germans Tjeerd, van Rossum Albert C, Marcus J Tim

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The response to cardiac resynchronization therapy (CRT), which is applied to patients with heart failure (HF) and left bundle-branch block (LBBB), can be predicted from the mechanical dyssynchrony measured on circumferential strain. Circumferential strain can be assessed by either 2D or 3D strain analysis. In this study was evaluated the difference between 2D and 3D circumferential strain using MR tagging with high temporal resolution (14 ms). Six healthy volunteers and five patients with LBBB were evaluated. We compared the 2D and 3D circumferential strains by computing the mechanical dyssynchrony and the cross correlation (r) between 2D and 3D strain curves, and by quantifying the differences in peak circumferential shortening, time to onset, and time to peak of shortening. The obtained maximum r(2) values were 0.97 +/- 0.03 and 0.87 +/- 0.16 for the healthy and LBBB populations, respectively, and thus showed a good similarity between 2D and 3D strain curves. No significant difference was observed between 2D and 3D in time to onset, time to peak, or peak circumferential shortening. Thus, to measure dyssynchrony, 2D strain analysis will suffice. Since 2D analysis is easier to implement than 3D analysis, this finding brings the application of MRI tagging and strain analysis closer to the clinical routine.

Для цитирования: Tecelão Sandra R R, Zwanenburg Jaco J M, Kuijer Joost P A, de Cock Carel C, Germans Tjeerd, van Rossum Albert C, Marcus J Tim. Quantitative comparison of 2D and 3D circumferential strain using MRI tagging in normal and LBBB hearts.. Magnetic resonance in medicine. 2007. DOI: 10.1002/mrm.21142.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.