MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3346/jkms.2006.21.6.989

Медицинская библиотека · Journal of Korean medical science · 2006

Complications of 2-D echocardiography guided transfemoral right ventricular endomyocardial biopsy.

Han Juyup, Park Yongwhi, Lee Hyunsang, Kang Hyunjae, Kim Hyungseop, Yang Dong Heon, Park Hun Sik, Cho Yongkeun, Chae Shung-Chull, Jun Jae-Eun, Park Wee-Hyun

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

Endomyocardial biopsy (EMBx) is a useful tool for diagnosing various cardiac pathologies. However, the routine use of EMBx has not gained widespread acceptance due to the possible complications related to the EMBx. Thus, not much information is available on the complications related to the EMBx. We prospectively evaluated 90 consecutive patients who underwent 2-D echocardiography guided transfemoral right ventricular EMBx at Kyungpook National University Hospital between March 2002 and November 2005 to determine the incidence, nature and subsequent management of complications related to EMBx. The clinical diagnoses before the EMBx were arrhythmogenic right ventricular dysplasia in 54, dilated cardiomyopathy in 19, Brugada syndrome in 9, myocarditis in 6 and miscellaneous in 2 patients. The overall major complication rate was 5.6% and no procedure-related mortality occurred. Myocardial perforation (n=3), which was the most frequent complication, did not progress to cardiac tamponade requiring pericardiocentesis in any patient. Hemodynamically unstable ventricular tachycardia occurred in 1 patient. New and persistent right bundle branch block occurred in another. Our findings suggest that 2-D echocardiography guided transfemoral right ventricular EMBx is a relatively safe procedure.

Для цитирования: Han Juyup, Park Yongwhi, Lee Hyunsang, Kang Hyunjae, Kim Hyungseop, Yang Dong Heon, Park Hun Sik, Cho Yongkeun, Chae Shung-Chull, Jun Jae-Eun, Park Wee-Hyun. Complications of 2-D echocardiography guided transfemoral right ventricular endomyocardial biopsy.. Journal of Korean medical science. 2006. DOI: 10.3346/jkms.2006.21.6.989.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.