MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacc.2006.04.103

Медицинская библиотека · Journal of the American College of Cardiology · 2006

Non-invasive detection of coronary artery disease in patients with left bundle branch block using 64-slice computed tomography.

Ghostine Saïd, Caussin Christophe, Daoud Béatrice, Habis Michel, Perrier Eric, Pesenti-Rossi David, Sigal-Cinqualbre Anne, Angel Claude-Yves, Lancelin Bernard, Capderou André, Paul Jean-François

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

The goal of this study was to evaluate the diagnostic accuracy of 64-slice computed tomography (CT) to identify coronary artery disease (CAD) in patients with complete left bundle branch block (LBBB).

BACKGROUND

Left bundle branch block increases risk of cardiac mortality, and prognosis is primarily determined by the underlying coronary disease. Non-invasive stress tests have limited performance, and conventional coronary angiography (CCA) is usually required.

METHODS

Sixty-six consecutive patients with complete LBBB and sinus rhythm admitted for CCA were enrolled. Computed tomography was performed 3 +/- 3.9 days before CCA. The accuracy of 64-slice CT to detect significant stenosis (>50% lumen narrowing) was compared with quantitative coronary angiography. All segments were analyzed regardless of image quality from coronary calcification or motion artifacts. Results were analyzed by patient and by coronary segment (990) using the American Heart Association 15-segment model.

RESULTS

Lower heart rates were associated with improved image quality. Computed tomography correctly identified 35 of 37 (95%) patients without significant stenosis and 28 of 29 (97%) patients with significant stenosis on CCA. Computed tomography correctly assessed 68 of 94 (72%) significant stenosis. Overall, accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of 64-slice CT for identifying CAD by patient was 95%, 97%, 95%, 93%, and 97%, respectively, and by segment was 97%, 72%, 99%, 91%, and 97%, respectively.

CONCLUSIONS

In a routine clinical practice, 64-slice CT detects with excellent accuracy a significant CAD in patients with complete LBBB. A normal CT in this clinical setting is a robust tool to act as a filter and avoid invasive diagnostic procedures.

Для цитирования: Ghostine Saïd, Caussin Christophe, Daoud Béatrice, Habis Michel, Perrier Eric, Pesenti-Rossi David, Sigal-Cinqualbre Anne, Angel Claude-Yves, Lancelin Bernard, Capderou André, Paul Jean-François. Non-invasive detection of coronary artery disease in patients with left bundle branch block using 64-slice computed tomography.. Journal of the American College of Cardiology. 2006. DOI: 10.1016/j.jacc.2006.04.103.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.