Journal of infection and chemotherapy : official journal of the Japan Society of Chemotherapy · 2022
A prospective clinical evaluation of the diagnostic accuracy of the SARS-CoV-2 rapid antigen test using anterior nasal samples.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Akashi Yusaku, Horie Michiko, Takeuchi Yuto, Togashi Kenichi, Adachi Yuki, Ueda Atsuo, Notake Shigeyuki, Nakamura Koji, Terada Norihiko, Kurihara Yoko, Kiyasu Yoshihiko, Suzuki Hiromichi
Аннотация
INTRODUCTION: The diagnostic accuracy of antigen testing of anterior nasal (AN) samples for the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection has not been evaluated in the Japanese population. This study assessed the diagnostic accuracy of the Roche SARS-CoV-2 rapid antigen test (rapid antigen test) using AN samples.
METHODS: Two AN samples and one nasopharyngeal (NP) sample were collected from individuals undergoing screening for SARS-CoV-2 infection. The results of the rapid antigen test and the reverse-transcription polymerase chain reaction (RT-PCR) test using AN samples were compared to those of RT-PCR tests using NP samples.
RESULTS: Samples were collected from 800 participants, 95 and 110 of whom tested positive for SARS-CoV-2 on RT-PCR tests of AN and NP samples, respectively. The overall sensitivity/specificity of the AN rapid antigen test and AN RT-PCR were 72.7%/100% and 86.4%/100%, respectively. In symptomatic cases, the sensitivities of the AN rapid antigen test and AN RT-PCR were 84.7% and 94.9%, respectively. In asymptomatic cases, the sensitivities of the AN rapid antigen test and AN RT-PCR were 58.8% and 76.5%, respectively. The sensitivity of the AN rapid antigen test was over 80% in cases with cycle threshold (Ct) values < 25; it significantly decreased with an increase in the Ct values (p < 0.001).
CONCLUSION: The rapid antigen test with AN samples had a favorable sensitivity, especially in symptomatic cases or in cases with Ct values < 25. It gave no false-positive results. Compared with AN-RT PCR, the AN rapid antigen test had a modestly lower sensitivity in asymptomatic cases.
METHODS: Two AN samples and one nasopharyngeal (NP) sample were collected from individuals undergoing screening for SARS-CoV-2 infection. The results of the rapid antigen test and the reverse-transcription polymerase chain reaction (RT-PCR) test using AN samples were compared to those of RT-PCR tests using NP samples.
RESULTS: Samples were collected from 800 participants, 95 and 110 of whom tested positive for SARS-CoV-2 on RT-PCR tests of AN and NP samples, respectively. The overall sensitivity/specificity of the AN rapid antigen test and AN RT-PCR were 72.7%/100% and 86.4%/100%, respectively. In symptomatic cases, the sensitivities of the AN rapid antigen test and AN RT-PCR were 84.7% and 94.9%, respectively. In asymptomatic cases, the sensitivities of the AN rapid antigen test and AN RT-PCR were 58.8% and 76.5%, respectively. The sensitivity of the AN rapid antigen test was over 80% in cases with cycle threshold (Ct) values < 25; it significantly decreased with an increase in the Ct values (p < 0.001).