MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jiac.2022.02.016

Медицинская библиотека · Journal of infection and chemotherapy : official journal of the Japan Society of Chemotherapy · 2022

A prospective clinical evaluation of the diagnostic accuracy of the SARS-CoV-2 rapid antigen test using anterior nasal samples.

Akashi Yusaku, Horie Michiko, Takeuchi Yuto, Togashi Kenichi, Adachi Yuki, Ueda Atsuo, Notake Shigeyuki, Nakamura Koji, Terada Norihiko, Kurihara Yoko, Kiyasu Yoshihiko, Suzuki Hiromichi

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

The diagnostic accuracy of antigen testing of anterior nasal (AN) samples for the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection has not been evaluated in the Japanese population. This study assessed the diagnostic accuracy of the Roche SARS-CoV-2 rapid antigen test (rapid antigen test) using AN samples.

METHODS

Two AN samples and one nasopharyngeal (NP) sample were collected from individuals undergoing screening for SARS-CoV-2 infection. The results of the rapid antigen test and the reverse-transcription polymerase chain reaction (RT-PCR) test using AN samples were compared to those of RT-PCR tests using NP samples.

RESULTS

Samples were collected from 800 participants, 95 and 110 of whom tested positive for SARS-CoV-2 on RT-PCR tests of AN and NP samples, respectively. The overall sensitivity/specificity of the AN rapid antigen test and AN RT-PCR were 72.7%/100% and 86.4%/100%, respectively. In symptomatic cases, the sensitivities of the AN rapid antigen test and AN RT-PCR were 84.7% and 94.9%, respectively. In asymptomatic cases, the sensitivities of the AN rapid antigen test and AN RT-PCR were 58.8% and 76.5%, respectively. The sensitivity of the AN rapid antigen test was over 80% in cases with cycle threshold (Ct) values < 25; it significantly decreased with an increase in the Ct values (p < 0.001).

CONCLUSION

The rapid antigen test with AN samples had a favorable sensitivity, especially in symptomatic cases or in cases with Ct values < 25. It gave no false-positive results. Compared with AN-RT PCR, the AN rapid antigen test had a modestly lower sensitivity in asymptomatic cases.

Для цитирования: Akashi Yusaku, Horie Michiko, Takeuchi Yuto, Togashi Kenichi, Adachi Yuki, Ueda Atsuo, Notake Shigeyuki, Nakamura Koji, Terada Norihiko, Kurihara Yoko, Kiyasu Yoshihiko, Suzuki Hiromichi. A prospective clinical evaluation of the diagnostic accuracy of the SARS-CoV-2 rapid antigen test using anterior nasal samples.. Journal of infection and chemotherapy : official journal of the Japan Society of Chemotherapy. 2022. DOI: 10.1016/j.jiac.2022.02.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.