OBJECTIVES

To evaluate the diagnostic utility of self-collected saliva in coronavirus desease-19 (COVID-19) screening procedures.

METHODS

A total of 6 databases were reviewed from their inception until August 2021. Sensitivity and specificity were measured by extracting items (true-positive, true-negative, false-positive and false-negative) from each paper. We evaluated the diagnostic accuracy based on Quality Assessment of Diagnostic Accuracy Studies, version 2.

RESULTS

A total of 41 studies were included in the final analysis. The diagnostic odds ratio (OR) of self-collected saliva was 196.2022 (95% confidence interval [CI]: 117.8833-326.5546). The area under the summary receiver operating characteristic curve was 0.955. For detecting COVID-19, self-collected saliva had a moderate sensitivity of 0.8476 [0.8045-0.8826] and positive predictive value of 0.9404 [0.9122-0.9599] but high specificity of 0.9817 [0.9707-0.9887] and negative predictive value of 0.9467 [0.9130-0.9678]. In a subgroup analysis, the diagnostic accuracy of self-collected saliva tended to be higher for symptomatic (vs. asymptomatic) examinees.

CONCLUSION

Although naso/oropharyngeal swab tests are the most accurate and important diagnostic tools, the saliva-based testing method can be used as a suitable alternative test, with the advantages of increased patient convenience, efficient testing, and the need for fewer medical staff and resources. In particular, simple collecting method such as drooling or spitting without coughing would be effective in evaluating the symptomatic patients.PROSPERO no.: CRD42021279287.

Для цитирования: Kim Do Hyun, Basurrah Mohammed A, Han Jae Hong, Kim Sung Won, Hwang Se Hwan. The diagnostic accuracy of RT-PCR from self-collected saliva versus nasopharyngeal sampling: A systematic review and meta-analysis.. Saudi medical journal. 2022. DOI: 10.15537/smj.2022.43.1.20210743.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.