MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacc.2004.03.045

Медицинская библиотека · Journal of the American College of Cardiology · 2004

Clinical, angiographic, and intravascular ultrasound characteristics of early saphenous vein graft failure.

Caños Daniel A, Mintz Gary S, Berzingi Chalak O, Apple Sue, Kotani Jun-ichi, Pichard Augusto D, Satler Lowell F, Suddath William O, Waksman Ron, Lindsay Joseph, Weissman Neil J

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

We sought to examine saphenous vein graft (SVG) lesions that fail within the first year after operation.

BACKGROUND

Saphenous vein grafts remain patent for approximately 10 years; however, up to 15% to 20% of SVGs become occluded within the first year.

METHODS

We studied 100 patients who underwent percutaneous coronary intervention (PCI) for early (<1 year post-implantation) SVG failure lesions and compared them with a diabetes- and hypercholesterolemia-matched cohort of late SVG failures (>1 year). Coronary angiography and intravascular ultrasound images were analyzed.

RESULTS

The majority of patients in both groups were males who presented with unstable angina; 36% were diabetic. Graft ages were 6.0 +/- 2.9 months and 105.4 +/- 50.8 months, respectively. The early SVG failure lesion location was more often ostial or proximal (62% vs. 42%, respectively). Early SVG failures were angiographically smaller than late failures (reference: 2.47 +/- 0.86 mm vs. 3.26 +/- 0.83 mm, p < 0.001) but had similar lesion lengths. Intravascular ultrasound showed that early failure lesions had smaller proximal and distal reference lumen areas (7.3 +/- 6.8 mm2 vs. 10.6 +/- 3.8 mm2, p = 0.026) and greater reference plaque burden than late failures (52.3% vs. 36.1%, p < 0.001). After PCI, 20.6% of early and 30.6% of late failure lesions had creatine kinase-myocardial band (CK-MB) greater than twice normal.

CONCLUSIONS

Early SVG failure is mostly proximal or ostial, lesions appear focal, and early SVGs appear smaller than late SVGs. Intravascular ultrasound shows significant reference segment plaque burden, suggesting more severe, diffuse SVG disease.

Для цитирования: Caños Daniel A, Mintz Gary S, Berzingi Chalak O, Apple Sue, Kotani Jun-ichi, Pichard Augusto D, Satler Lowell F, Suddath William O, Waksman Ron, Lindsay Joseph, Weissman Neil J. Clinical, angiographic, and intravascular ultrasound characteristics of early saphenous vein graft failure.. Journal of the American College of Cardiology. 2004. DOI: 10.1016/j.jacc.2004.03.045.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.