MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ajh.20074

Медицинская библиотека · American journal of hematology · 2004

Determinants of ELISA D-dimer sensitivity for unstable angina pectoris as defined by coronary catheterization.

Shitrit David, Bar-Gil Shitrit Ariella, Rudensky Bernard, Sulkes Jaqueline, Tzviony Dan

СтатьяПеревод пока не подготовлен

Аннотация

Unstable angina pectoris is associated with elevated D-dimer levels. However, the operating characteristics (sensitivity, specificity, positive and negative predictive value) of the D-dimer assay for the diagnosis of coronary artery disease (CAD) are unknown. Using a prospective, observational design, we collected blood from 54 patients with unstable angina pectoris at admission and assayed for ELISA D-dimer levels. The sensitivity, specificity, and negative and positive prediction values for angiographically determined coronary artery disease were calculated at multiple discriminate levels. All patients underwent coronary catheterization. A statistically significant correlation was noted between ELISA D-dimer levels and age, male sex, hypertension, use of beta-blocker, fibrinogen levels and catheterization findings. No correlation was noted between ELISA D-dimer levels and degree of the coronary artery disease. Best results were provided at a discriminate level of 270 ng/ml, with sensitivity 70%, negative predictive value 72%, and overall accuracy 67%. All discriminate levels, however, provided values too low for diagnosis. In conclusion, ELISA D-dimer assay is a non-sensitive, non-specific test for coronary artery disease as defined by coronary catheterization. However, the assay adds information regarding the severity of disease in patients presenting with acute coronary syndrome.

Для цитирования: Shitrit David, Bar-Gil Shitrit Ariella, Rudensky Bernard, Sulkes Jaqueline, Tzviony Dan. Determinants of ELISA D-dimer sensitivity for unstable angina pectoris as defined by coronary catheterization.. American journal of hematology. 2004. DOI: 10.1002/ajh.20074.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.