MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/eja.0b013e32832c7848

Медицинская библиотека · European journal of anaesthesiology · 2009

A comparison of the Laryngopharyngeal Examination blade and the English Macintosh laryngoscope blade using an intubating manikin: a prospective randomized crossover study.

Ashfaque Muhammad, Mason Jonathan, Al-Shaikh Baha, Adegoke Kenneth

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVE

To compare the new design laryngoscope blade, Laryngopharyngeal Examination blade, with the English Macintosh blade for examination of the laryngopharynx and placement of a nasogastric tube in the presence of a tracheal tube, time taken to insert the nasogastric tube and for tracheal intubation in an adult intubation manikin.

METHODS

A prospective randomized and crossover trial with 81 anaesthetists of different expertise taking part in the study. Ease of laryngoscopy and tracheal intubation, examination of hypopharynx and time taken to insert the nasogastric tube were measured using the new design laryngoscope blade compared with the Macintosh blade in a manikin.

RESULTS

Using the new design blade, examination of the hypopharynx was found easier by 75% of participants and insertion of nasogastric tube after tracheal intubation was found easier by 77% of participants. Time taken to insert the nasogastric tube was shorter with the new design blade. Ease of laryngoscopy and tracheal intubation using the new design laryngoscope blade was found to be comparable or superior to the Macintosh blade by 68% of the participants.

CONCLUSION

We conclude that, in a manikin, the new design blade can make nasogastric tube insertion easier when compared with the Macintosh blade and it can be used to facilitate laryngoscopy and tracheal intubation. Further studies are needed to evaluate its use in patients.

Для цитирования: Ashfaque Muhammad, Mason Jonathan, Al-Shaikh Baha, Adegoke Kenneth. A comparison of the Laryngopharyngeal Examination blade and the English Macintosh laryngoscope blade using an intubating manikin: a prospective randomized crossover study.. European journal of anaesthesiology. 2009. DOI: 10.1097/eja.0b013e32832c7848.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.