MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/tmi.2016.2593900

Медицинская библиотека · IEEE transactions on medical imaging · 2016

Simultaneous Analysis of 2D Echo Views for Left Atrial Segmentation and Disease Detection.

Allan Gregory, Nouranian Saman, Tsang Teresa, Seitel Alexander, Mirian Maryam, Jue John, Hawley Dale, Fleming Sarah, Gin Ken, Swift Jody, Rohling Robert, Abolmaesumi Purang

СтатьяПеревод пока не подготовлен

Аннотация

We propose a joint information approach for automatic analysis of 2D echocardiography (echo) data. The approach combines a priori images, their segmentations and patient diagnostic information within a unified framework to determine various clinical parameters, such as cardiac chamber volumes, and cardiac disease labels. The main idea behind the approach is to employ joint Independent Component Analysis of both echo image intensity information and corresponding segmentation labels to generate models that jointly describe the image and label space of echo patients on multiple apical views, instead of independently. These models are then both used for segmentation and volume estimation of cardiac chambers such as the left atrium and for detecting pathological abnormalities such as mitral regurgitation. We validate the approach on a large cohort of echoes obtained from 6,993 studies. We report performance of the proposed approach in estimation of the left-atrium volume and detection of mitral-regurgitation severity. A correlation coefficient of 0.87 was achieved for volume estimation of the left atrium when compared to the clinical report. Moreover, we classified patients that suffer from moderate or severe mitral regurgitation with an average accuracy of 82%.

Для цитирования: Allan Gregory, Nouranian Saman, Tsang Teresa, Seitel Alexander, Mirian Maryam, Jue John, Hawley Dale, Fleming Sarah, Gin Ken, Swift Jody, Rohling Robert, Abolmaesumi Purang. Simultaneous Analysis of 2D Echo Views for Left Atrial Segmentation and Disease Detection.. IEEE transactions on medical imaging. 2016. DOI: 10.1109/tmi.2016.2593900.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.