MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1001/archsurg.134.8.824

Медицинская библиотека · Archives of surgery (Chicago, Ill. : 1960) · 1999

Parathyroid localization with high-resolution ultrasound and technetium Tc 99m sestamibi.

Purcell G P, Dirbas F M, Jeffrey R B, Lane M J, Desser T, McDougall I R, Weigel R J

СтатьяПеревод пока не подготовлен

Аннотация

HYPOTHESIS: High-resolution ultrasound and technetium Tc 99m sestamibi scanning can be used for preoperative localization of abnormal parathyroid glands in patients with hyperparathyroidism.

DESIGN

Ultrasound and sestamibi scanning were performed in patients undergoing neck exploration for hyperparathyroidism. If the 2 scans agreed in identifying a single adenoma, and surgery confirmed the location of a single adenoma and an ipsilateral normal gland, a unilateral exploration was performed.

SETTING

University tertiary care center.

PATIENTS: Sixty-one consecutive patients undergoing surgery for hyperparathyroidism from September 1, 1994, through September 30, 1997.

INTERVENTIONS: High-resolution ultrasound was performed in 59 patients and sestamibi scanning in 58 patients; all patients underwent neck exploration by a single surgeon.

MAIN OUTCOME MEASURES: The results of preoperative ultrasound and sestamibi scanning were compared with operative and histological findings.

RESULTS

All patients were cured of hypercalcemia. Specificity of ultrasound and sestamibi scanning was 98% and 99%, respectively; however, their sensitivity was only 57% and 54%, respectively. Both imaging modalities had lower sensitivities in the setting of multigland disease. If both imaging studies were considered as a single test, sensitivity for imaging in patients with primary hyperparathyroidism reached 78%. Our localization protocol allowed a unilateral approach in 43% of patients (23 of 53).

CONCLUSIONS

These results confirm the value of preoperative localization in patients with hyperparathyroidism. A unilateral approach can be used with a high degree of success in cases when ultrasound and sestamibi scanning agree in the identification of a single adenoma confirmed by surgical exploration with the identification of a normal ipsilateral gland.

Для цитирования: Purcell G P, Dirbas F M, Jeffrey R B, Lane M J, Desser T, McDougall I R, Weigel R J. Parathyroid localization with high-resolution ultrasound and technetium Tc 99m sestamibi.. Archives of surgery (Chicago, Ill. : 1960). 1999. DOI: 10.1001/archsurg.134.8.824.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.