[Isotopic study with double phase 99mTc-sestamibi in the localization of parathyroid gland lesions].

Bernà L, Piera J, Rodríguez-Espinosa J, Caixàs A, Puig-Domingo M, Farrerons J, Galofré M, Rousaud F, Matías-Guiu X, Estorch M, Carrió I

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The use of preoperative imaging in patients with hyperparathyroidism remains controversial. The aim of this study is to assess the usefulness of the double-phase 99mTc-sestamibi scintigraphy in the diagnosis of abnormal parathyroid glands in patients with primary hyperparathyroidism.

PATIENTS AND

METHODS

We studied 60 patients presenting with primary hyperparathyroidism who were referred to surgery; four of them had been unsuccessfully operated. 99mTc-sestamibi scintigraphy were performed in all patients previously to surgery. Scintigraphic technique: planar imaging of the neck and thorax was done in the anterior view at 15 and 150 min postinjection of 740 MBq (20 mCi) of 99mTc-sestamibi.

RESULTS

Surgery found 57 adenomas (2.59 [SD, 5.84] g; range 0.160-40), 6 hyperplastic glands (0.34 [SD, 0.26] g) and one carcinoma 8.2 g. The 99mTc-sestamibi was able to localize correctly 60 out of 64 lesions (55/57 adenomas, 4/6 hyperplastic glands and 1/1 carcinoma) (global sensitivity of 94%, adenomas sensitivity of 96%, positive predictive value of 97% and specificity of 98%). Isotopic imaging detected the abnormal tissue in all patients who had undergone unsuccessful previous surgery. PTH (4 [SD, 1.51] pmol/l) and calcium postoperative serum levels (2.13 [SD, 0.22] mmol/l) showed curation of all patients.

CONCLUSION

Double phase parathyroid scintigraphy with 99mTc-sestamibi is the method of choice to localize abnormal parathyroid glands.

Для цитирования: Bernà L, Piera J, Rodríguez-Espinosa J, Caixàs A, Puig-Domingo M, Farrerons J, Galofré M, Rousaud F, Matías-Guiu X, Estorch M, Carrió I. [Isotopic study with double phase 99mTc-sestamibi in the localization of parathyroid gland lesions].. Medicina clinica. 1999.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.