DOI 10.1016/j.jcms.2013.04.001
One-step primary reconstruction for complex craniofacial resection with PEEK custom-made implants.
Аннотация
PURPOSE: Reconstruction of large craniofacial defects has largely improved since custom-made implants have been developed in the past decade. For large lesions in fronto-orbital region (such as osteomeningioma), we applied a simple and reliable protocol to perform optimal primary reconstruction with PEEK (polyetheretherketone) specific implant at the same time of the resection.
MATERIAL AND
METHODS
Our protocol is based on virtual preoperative surgery with a planned bone resection that allows engineering of a specific implant to accurately fit to the defect during the surgery. Thus tumour removal and optimal immediate reconstruction are performed easily in a single-step procedure. The use of navigation is required to perform accurate resection according to the planning. We report our experience in five patients requiring complex orbito-frontal reconstruction.
RESULTS
Planned resection was always achieved with accurate placement of the implant. Optimal orbital reconstruction is allowed and permits exophthalmos correction and orbital contour symmetry. No major complication was observed.
CONCLUSION
We provide a simple one-step technique to reconstruct the orbit while achieving symmetric cosmetic and functional results, reducing operative time and avoiding donor site morbidity.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.