MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10840-022-01165-5

Медицинская библиотека · Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2022

Intuitive diagnosis of complex atrial tachycardia mechanisms using a novel histogram module of an ultra-high-resolution mapping system.

Tanaka Yasuaki, Takahashi Atsushi, Kawaguchi Naohiko, Nakashima Emiko, Takagi Katsumasa, Okubo Kenji, Hikita Hiroyuki, Sasano Tetsuo

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The LUMIPOINT™ software module was developed to aid the physician in determining the mechanism of individual atrial tachycardias (ATs). The purpose of this study was to assess the clinical utility of the SKYLINE™ histogram that is a part of LUMIPOINT™.

METHODS

This study included consecutive patients with iatrogenic sustained AT who underwent catheter ablation using conventional mapping (RHYTHMIA™). SKYLINE™ patterns were analyzed offline and classified into two types: (1) focal type (type-F) exhibiting a low-amplitude (relative activating surface area < 10%) plateau period and (2) reentrant type (type-R) showing no plateau period. How well the two patterns distinguished between focal and macroreentrant ATs as determined by conventional mapping was evaluated.

RESULTS

We studied 101 iatrogenic ATs in 91 patients (female: 24, mean age: 67.3 ± 9.1 years). Activation mapping revealed 79 (78.2%) macroreentrant, 6 (5.9%) localized reentrant, and 16 (15.8%) focal ATs. Among the 72 type-R ATs, the mechanism was truly a macroreentry in 70 ATs. However, one focal AT and one localized reentrant AT displayed a type-R pattern (pseudo-reentry pattern). In the 29 type-F ATs, nine macroreentrant ATs were recognized (pseudo-focal pattern). Using SKYLINE™ type-R to differentiate macroreentrant AT from AT with centrifugal activation (focal or localized reentry), the sensitivity and specificity were 88.6% and 90.9%, respectively. Even when the SKYLINE™ type did not match the mapping-based AT mechanism, all discrepancies were electrophysiologically explicable using the SKYLINE™ histograms.

CONCLUSIONS

SKYLINE™ histograms are a useful tool for the intuitive diagnosis of AT mechanisms.

Для цитирования: Tanaka Yasuaki, Takahashi Atsushi, Kawaguchi Naohiko, Nakashima Emiko, Takagi Katsumasa, Okubo Kenji, Hikita Hiroyuki, Sasano Tetsuo. Intuitive diagnosis of complex atrial tachycardia mechanisms using a novel histogram module of an ultra-high-resolution mapping system.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2022. DOI: 10.1007/s10840-022-01165-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.