m+Medelevator.RU
← Поиск публикаций
Journal of cardiovascular electrophysiology · 2022

Targeted cluster ablation of non-CTI-dependent atrial arrhythmias in congenital heart disease using ultrahigh-definition mapping.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kefala Anna, Claridge Simon, Wijayagoonawardana Pradeep, Sadagopan Shankar, Ullah Waqas, Yue Arthur

Аннотация

BACKGROUND: Ablation of atrial arrhythmias in patients with congenital heart disease (CHD) has markedly improved with advanced mapping systems. However, recurrence rates remain high. The linear ablation strategy is not uncommonly practiced necessitating prolonged ablation times. We report the outcomes of adopting a strategy of minimal, cluster delivery of radiofrequency (RF) energy at critical substrates identified by ultrahigh-definition mapping for atrial arrhythmias in patients with CHD.

METHODS: Non-cavotricuspid isthmus (non-CTI) atrial tachycardias were ablated with a targeted ablation cluster technique (TACT) using an ultrahigh-density mapping system combined with multielectrode monitoring and endpoint determination in preference to linear ablation. The arrhythmia substrates, RF times, and acute- and medium-term success rates were studied.

RESULTS: Fifty-eight tachycardias were mapped and ablated in 42 procedures: 34 non-CTIs and 24 CTIs. A targeted ablation cluster was performed for non-CTI tachycardias, with a median ablation time of 3.1 min. In 53% of non-CTI tachycardias, arrhythmia termination was achieved with ≤2 RF applications. After a mean follow-up of 23.6 months, 27 (80%) patients were free of recurrent atrial arrhythmias. One of 34 targeted non-CTI tachycardia recurred, with a final success rate of 91%. Linear ablation was performed for CTI flutters with a median ablation time of 6.8 min (vs. non-CTIs, p = .006). Three of 21 tachycardias recurred due to reconnection of the ablation line but the final success rate was 100%.

CONCLUSIONS: The TACT approach for non-CTI atrial arrhythmias in congenital patients as guided by the ultrahigh-density mapping is an effective method with short ablation times and excellent medium-term outcomes.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты