m+Medelevator.RU
← Поиск публикаций
Heart rhythm · 2011

Effect of electrocardiographic lead placement on localization of outflow tract tachycardias.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Anter Elad, Frankel David S, Marchlinski Francis E, Dixit Sanjay

Аннотация

BACKGROUND: The origin of outflow tract ventricular tachycardia (OTVT) can be predicted from a surface electrocardiogram: indexes of R-wave amplitudes in leads V(1) and V(2) are used to differentiate a right origin from a left origin, while the axis of lead I differentiates an anterior origin from a posterior origin. Incorrect electrode placement is clinically common and may alter predictability of OTVTs.

OBJECTIVE: To explore the influence of vertical deviation in leads V(1) and V(2) and arm lead position on the QRS morphology of OTVTs.

METHODS: Vertical deviation of leads V(1) and V(2) was studied in 18 patients with OTVTs. Ventricular premature depolarization beats were recorded in the standard position, superior position, and inferior position. The effect of arm lead position was studied in a separate cohort of 16 patients: ventricular premature depolarizations were recorded with limb leads positioned over the shoulders and over the chest. The origin of tachycardia was determined by using activation mapping and confirmed by successful ablation.

RESULTS: Superior displacement of leads V(1) and V(2) reduced the R-wave amplitude and led to a decreased R/S ratio (0.11 ± 0.09 vs 0.17 ± 0.1; P <.01), while inferior displacement of leads V(1) and V(2) resulted in an increased R-wave amplitude and led to an increased R/S ratio (0.46 ± 0.35 vs 0.17 ± 0.1; P <.01). Anterior displacement of the arm leads from shoulders to chest resulted in the reduction in the R-wave amplitude in lead I (0.25 ± 0.30 mV vs 0.04 ± 0.43 mV; P <.05).

CONCLUSIONS: Small changes in electrocardiographic electrode placement markedly alter the QRS morphology of OTVTs and thus alter the predictability of OTVT origin. These deviations are well within the range of clinical application and have the potential to misdirect ablation procedures.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты