MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00392-003-0920-9

Медицинская библиотека · Zeitschrift fur Kardiologie · 2003

[Ross procedure with combined replacement of the ascending aorta: impact on autograft root function and distensibility].

Leyh R G, Kofidis T, Hagl C, Fischer S, Knobloch K, Akhyari P, Karck M, Haverich A

Сравнительное исследованиеАннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The safety and effectiveness of combined aortic root autograft replacement in combination with ascending aorta replacement has been demonstrated recently. Replacement of the ascending aorta with a vascular prosthesis results in an increase in aortic root distension, and aortic root wall stress. In this study we aimed to assess the autograft root dimensions, distensibility, and autograft valve function in patients after Ross operation combined with replacement of the ascending aorta compared to patients who underwent Ross operation only.

PATIENTS AND

METHODS

Echocardiographic follow-up was performed on 28 patients after Ross operation with complete root replacement only (group R) and 12 patients who received an additional replacement of the ascending aorta (group R/A). The mean follow-up time was 24.9 +/- 17.2 months. Autograft root dimensions, root distensibility and valve function were assessed by echo-cardiography. The aortic root was measured at the level of the annulus, sinus of valsalva, and sinotubular junction. The distensibility was calculated as percent change of radius.

RESULTS

The mean distensibility at the annulus level was higher in group R/A (18.4 +/- 6.8% vs 13.4 +/- 8.1%; p = 0.047); at the level of the sinus of valsalva and sinotubular junction no differences were observed. The autograft pressure gradient was within physiological limits in all patients. The majority of patients showed a competent autograft valve (group R: AI 0 degree; 83%, AI I degree; 14%, AI II degree; 3%; group R/A: AI 0 degree; 75%, AI I degree; 25%).

CONCLUSIONS

Replacement of the ascending aorta with a non-compliant prosthesis does not effect root dimension, distensibility, and valve function.

Для цитирования: Leyh R G, Kofidis T, Hagl C, Fischer S, Knobloch K, Akhyari P, Karck M, Haverich A. [Ross procedure with combined replacement of the ascending aorta: impact on autograft root function and distensibility].. Zeitschrift fur Kardiologie. 2003. DOI: 10.1007/s00392-003-0920-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.