The Annals of thoracic surgery · 2003
Replacement of the aortic valve in patients under 50 years of age: long-term follow-up of the St. Jude Medical prosthesis.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Emery Robert W, Erickson Carla A, Arom Kit V, Northrup William F, Kersten Thomas E, Von Rueden Thomas J, Lillehei Theodore J, Nicoloff Demetre M
Аннотация
BACKGROUND: Aortic valve replacement in the young adult (aged 18 to 50 years) is a choice between a mechanical prosthesis with attendant lifelong anticoagulation or biological prostheses of varying types that may have limited life expectancy in this age group.
METHODS: The Cardiac Surgical Research Foundation database was accessed to determine long-term outcomes in patients having aortic valve replacement with the St. Jude Medical Valve. This database has been privately maintained since the world's first St. Jude Medical (SJM) valve implant in 1977. Patients were contacted by questionnaire or by telephone if the survey was not returned. Follow-up was 93% complete.
RESULTS: From October 1977 through October 1997, 271 patients less than 50 years of age had isolated aortic valve replacement. Follow-up was 1957 patient years. Thirty-day operative mortality was 1.1% with 18 late deaths, 4 of which were valve related. Ninety percent of survivor INR responses indicated a frequency of monthly INR checks or less. Valve-related events including percent per patient year and mortality related to these events included thromboembolism, 6 episodes (0.3% per patient year, no deaths); anticoagulant-related bleeding, 6 events (0.3% per patient year, 2 deaths); paravalvular leak, 6 events (0.3% per patient year, 2 deaths); valve thrombosis, 2 events (0.1% per patient year, no deaths); and endocarditis, 3 events (0.15% per patient year, no deaths). There was no incidence of structural valve failure.
CONCLUSIONS: The SJM valve has a long record of excellent performance with durability lasting more than 20 years. The incidence of untoward events is low and death over time due to valve-related complications is low (4 of 271). The SJM valve has become our valve of choice for younger patients.
METHODS: The Cardiac Surgical Research Foundation database was accessed to determine long-term outcomes in patients having aortic valve replacement with the St. Jude Medical Valve. This database has been privately maintained since the world's first St. Jude Medical (SJM) valve implant in 1977. Patients were contacted by questionnaire or by telephone if the survey was not returned. Follow-up was 93% complete.
RESULTS: From October 1977 through October 1997, 271 patients less than 50 years of age had isolated aortic valve replacement. Follow-up was 1957 patient years. Thirty-day operative mortality was 1.1% with 18 late deaths, 4 of which were valve related. Ninety percent of survivor INR responses indicated a frequency of monthly INR checks or less. Valve-related events including percent per patient year and mortality related to these events included thromboembolism, 6 episodes (0.3% per patient year, no deaths); anticoagulant-related bleeding, 6 events (0.3% per patient year, 2 deaths); paravalvular leak, 6 events (0.3% per patient year, 2 deaths); valve thrombosis, 2 events (0.1% per patient year, no deaths); and endocarditis, 3 events (0.15% per patient year, no deaths). There was no incidence of structural valve failure.
CONCLUSIONS: The SJM valve has a long record of excellent performance with durability lasting more than 20 years. The incidence of untoward events is low and death over time due to valve-related complications is low (4 of 271). The SJM valve has become our valve of choice for younger patients.
Предметные рубрики MeSH
AdolescentAdultAnticoagulantsAortic ValveAortic Valve InsufficiencyAortic Valve StenosisCause of DeathEquipment Failure AnalysisFemaleFollow-Up StudiesHeart Valve ProsthesisHumansInternational Normalized RatioMaleMiddle AgedPostoperative ComplicationsProduct Surveillance, PostmarketingProsthesis DesignSurvival RateThromboembolism