BACKGROUND

Double sequential defibrillation (DSD) has been proposed as a viable treatment option for patients in refractory ventricular fibrillation/pulseless ventricular tachycardia (VF/pVT) out-of-hospital cardiac arrests (OHCA). However, currently there is insufficient evidence to support a widespread implementation of this therapy.

STUDY

OBJECTIVES

The aim of this scoping review was to summarize the current available evidence of DSD for patients with refractory VF/pVT OHCA as well as to identify gaps in the literature that may require further research.

METHODS

We conducted a comprehensive literature search of MEDLINE via PubMed, Embase via Ovid, and Scopus on August 19, 2019. We also checked reference lists of relevant papers to identify additional studies. Any controlled clinical study design (randomized controlled trials and non-randomized controlled trials), and observational studies (cohort studies and case-control studies) providing information on resuscitative parameters, survival rates and neurological outcomes in adults (≥ 18 years old) treated with DSD for refractory VF/pVT OHCA were included. Two investigators independently conducted the literature search, study selection, and data extraction.

RESULTS

The search yielded 1612 unique records, of which 4 peer-reviewed articles were found relating to the research purpose, totaling 1061 patients of who 20.5% (n = 217) received DSD. Most studies evaluated if pre-hospital DSD was associated with improved survival to discharge after refractory VF/pVT. No randomized controlled trials were identified.

CONCLUSION

To date, it is difficult to conclude the real benefit of DSD for patients in refractory VF based on the available evidence. The findings of this scoping review suggest there is limited evidence to support at large-scale the use of DSD for refractory VF/pVT OHCA. Further research is needed to better characterize and understand the use of DSD for refractory VF/pVT, in order to implement best practices to maximize the effectiveness and efficiency of care.

Для цитирования: Miraglia Dennis, Miguel Lourdes A, Alonso Wilfredo, Ayala Jonathan E. Double sequential defibrillation for out-of-hospital refractory ventricular fibrillation: A scoping review.. The American journal of emergency medicine. 2019. DOI: 10.1016/j.ajem.2019.12.047.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.