MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/09593985.2018.1474404

Медицинская библиотека · Physiotherapy theory and practice · 2018

Accuracy of a single measurement site for self-monitoring of patients with breast cancer at risk for lymphedema.

Hidding Janine T, Beurskens Carien H G, De Vries Marijke T, Nijhuis-van der Sanden Maria W G, van Laarhoven Hanneke W M, van der Wees Philip J

СтатьяПеревод пока не подготовлен

Аннотация

Purpose: Early detection of breast cancer-related lymphedema through simple self-monitoring techniques may lead to early treatment and improved outcomes.

Methods

Prospective study of circumference measurements at four time points before, during, and after adjuvant chemotherapy with docetaxel, doxorubicin, and cyclophosphamide. Volume was calculated using the 10-cm interval circumference measurement method (reference test) and percentage difference between arms, for volume and circumference, was determined. First, the most valid single measurement location was determined by calculating Pearson's correlation coefficient relative to the reference test. Second, to evaluate the responsiveness to change over four time points, outcomes of the selected single measurement and the reference test were analyzed by repeated-measures ANOVA. Third, area under the curve (AUC) was used to determine the optimal sensitivity and specificity of the selected single measurement site (index test). Relationship between lymphedema (yes/no) and heaviness and swelling (yes/no) was analyzed using phi-coefficient.

Results

The measurement point 30 cm proximal to the styloid process showed the highest correlation with percentage difference in total arm volume (r = 0.80) and detected increased percentage difference between arms after treatment. Analyses showed high accuracy (AUC = 0.94; 95% CI 0.90-0.99) and good sensitivity (0.85) and specificity (0.85) using a cutoff score of 4% circumference difference between arms at this location. A moderate correlation between feelings of heaviness and swelling to lymphedema was observed (rφ = 0.64).

Conclusions

Circumference difference between arms of 4% measured at 30 cm proximal to the styloid process can be used as a surveillance site for further monitoring of patients at risk for lymphedema and may contribute to early diagnosis. Feelings of heaviness or swelling have moderate relationship with lymphedema, which needs to be confirmed in clinical practice.

Для цитирования: Hidding Janine T, Beurskens Carien H G, De Vries Marijke T, Nijhuis-van der Sanden Maria W G, van Laarhoven Hanneke W M, van der Wees Philip J. Accuracy of a single measurement site for self-monitoring of patients with breast cancer at risk for lymphedema.. Physiotherapy theory and practice. 2018. DOI: 10.1080/09593985.2018.1474404.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.