m+Medelevator.RU
← Поиск публикаций
Surgery for obesity and related diseases : official journal of the American Society for Bariatric Surgery · 2023

Side-to-side magnetic duodeno-ileostomy in adults with severe obesity with or without type 2 diabetes: early outcomes with prior or concurrent sleeve gastrectomy.

Многоцентровое исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Gagner Michel, Almutlaq Lamees, Cadiere Guy-Bernard, Torres Antonio J, Sanchez-Pernaute Andres, Buchwald Jane N, Abuladze David

Аннотация

BACKGROUND: Conventional metabolic/bariatric surgical anastomoses with sutures/staples may cause severe adverse events (AEs).

OBJECTIVES: The study aim was to evaluate the feasibility, safety, and effectiveness of primary and revisional side-to-side duodeno-ileostomy (DI) bipartition using a novel magnetic compression anastomosis device (Magnet Anastomosis System [MS]).

SETTING: Multicenter: private practices and university hospitals.

METHODS: In patients with body mass index ([BMI, kg/m2] ≥35.0 to ≤50.0 with/without type 2 diabetes [T2D] glycosylated hemoglobin [HbA1C > 6.5 %]), two linear MS magnets were delivered endoscopically to the duodenum and ileum with laparoscopic assistance and aligned, initiating magnet fusion and gradual DI (MagDI). The MagDI-after-SG group had undergone prior sleeve gastrectomy (SG); the MagDI + SG group underwent concurrent SG. AEs were graded by Clavien-Dindo Classification (CDC).

RESULTS: Between November 22, 2021 and May 30, 2023, 43 patients (88.0% female, mean age 43.7 ± 1.3 years) underwent the study procedures. The MS met feasibility criteria of magnet device placement, creation of patent anastomoses confirmed radiologically, and magnet passage in 100.0% of patients. There were 64 AEs, most were CDC grade I and II, significantly fewer in the MagDI-after-SG group (P < .001). No device-related AEs including anastomotic leakage, bleeding, obstruction, infection, or death. The MagDI-after-SG group experienced 6-month mean weight loss of 8.0 ± 2.5 kg (P < .01), 17.4 ± 5.0% excess weight loss (EWL). The MagDI + SG group had significantly greater weight loss (34.2 ± 1.6 kg, P < .001), 66.2 ± 3.4% EWL. All patients with T2D improved.

CONCLUSIONS: In early results of a multicenter study, the incisionless, sutureless Magnet System formed patent, complication-free anastomoses in side-to-side DI with prior or concurrent SG.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты