MedElevator Войти в исследования
← Поиск публикаций

DOI 10.64898/2026.08.03.26359612

Медицинская библиотека · medRxiv : the preprint server for health sciences · 2026

BioDeformUNet: A Deep Learning Model for Biomechanically Informed Liver Image Registration.

Zhang Xinyue, O'Connor Caleb S, Castelo Austin, Woodland McKell E, Daoud Bilel, Paolucci Iwan, Albuquerque Jessica, Altaie Mais, Siddiqi Noreen, Patel Ankit B, Odisio Bruno C, Brock Kristy K

СтатьяПрепринтПеревод пока не подготовлен

Аннотация

PURPOSE: To build a 3D U-Net model, BioDeformUNet, to predict the liver's deformation vector field (DVF) in near real-time, for efficient intra-procedural evaluation of the minimal ablative margin (MAM).

MATERIALS AND

METHODS

This retrospective study included 170 contrast-enhanced computed tomography (CECT) image pairs from 157 patients who underwent liver ablation treatment between 2020-2024. Each data instance included one pre-ablation CECT (pre-CECT) and one post-ablation CECT (post-CECT). BioDeformUNet was trained under the guidance of DVFs generated by a biomechanical model-based deformable image registration (DIR) algorithm using a loss function that focused on large liver deformations. Data were split patient-wise into training (92-93 patients), validation (23-24 patients), and testing sets (42 patients). We compared our method's performance with two deep learning-based DIR methods: VoxelMorph and VFA. Evaluation metrics included: target registration error (TRE), Dice similarity coefficient (DSC), Minimum Ablation Margin (MAM), and inference time. For BioDeformUNet, we additionally evaluated the accuracy of the deformed tumor center-of-mass mapping by comparing the predicted tumor center location with that generated by Morfeus. A mapping error less than 3.0 mm (corresponding to the voxel size) was considered accurate. We used the Wilcoxon signed-rank test to assess the significancy of each test result. Our code is available at https://github.com/XinyueZhang831/BioDeformUNET.

RESULTS

The TRE of BioDeformUNet was not significantly different from Morfeus (3.31±1.17 BioDeformUNet; 3.23±1.06 Morfeus; p-value=0.41). The BioDeformUNet DVF magnitude was within 3.0 mm of Morfeus DVF for an average of 91.9 ± 17.6% (mean ± SD) of the voxels. Tumor mapping errors greater than 3.0 mm occurred in only 8 cases. The inference time of BioDeformUNet was 0.6s per image pair, 0.2s for VoxelMorph, 0.3s for VFA, and 20.2s for Morfeus.

CONCLUSION

BioDeformUNet achieved a similar performance to the biomechanical model-based algorithm but required fewer computational operations, resulting in a 34× speedup in DVF computation.

Для цитирования: Zhang Xinyue, O'Connor Caleb S, Castelo Austin, Woodland McKell E, Daoud Bilel, Paolucci Iwan, Albuquerque Jessica, Altaie Mais, Siddiqi Noreen, Patel Ankit B, Odisio Bruno C, Brock Kristy K. BioDeformUNet: A Deep Learning Model for Biomechanically Informed Liver Image Registration.. medRxiv : the preprint server for health sciences. 2026. DOI: 10.64898/2026.08.03.26359612.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.