International journal of cardiology · 2014

Impact of cytochrome P450 2C19 loss-of-function polymorphism on intra-stent thrombi and lesion outcome after everolimus-eluting stent implantation compared to that after first-generation drug-eluting stent implantation.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Konishi Akihide, Shinke Toshiro, Otake Hiromasa, Nishio Ryo, Sawada Takahiro, Takaya Tomofumi, Nakagawa Masayuki, Osue Tsuyoshi, Taniguchi Yu, Iwasaki Masamichi, Kinutani Hiroto, Masaru Kuroda, Takahashi Hachidai, Terashita Daisuke, Shite Junya, Hirata Ken-ichi

Аннотация

BACKGROUND: The contribution of clopidogrel response due to cytochrome P450 (CYP) 2C19 loss-of-function polymorphism after drug-eluting stent (DES) implantation is unclear.

METHODS: A total of 196 patients who had undergone optical coherence tomography (OCT) at 8 months following first-generation DES (120 lesions) and current-generation everolimus-eluting stent (EES) implantation (127 lesions) were enrolled. Patients were divided into 3 groups by CYP2C19 polymorphism: extensive metabolizers (EMs), intermediate metabolizers (IMs), and poor metabolizers (PMs). OCT findings were compared among the 3 groups. Responsiveness to clopidogrel was assessed by VerifyNow platelet reactivity unit (PRU).

RESULTS: The incidence of intra-stent thrombi was significantly higher after first-generation DES implantation compared with EES implantation (35% vs 13%, respectively; p=0.0001). In the first-generation DES group, the incidence of intra-stent thrombi significantly increased among EMs, IMs, and PMs (21% vs 36% vs 63%, respectively; p=0.007), while there was no significant difference among the 3 groups after EES implantation (10% vs 13% vs 20%, respectively; p=0.55). The PRU significantly increased among EMs, IMs, and PMs in each stent group. In multivariate analyses, although PMs had a 3-fold higher risk of thrombi formation compared with non-PMs after first-generation DES implantation, there were no significant differences in thrombi formation between the 2 groups after EES implantation. The optimal PRU cutoff values for the prediction of intra-stent thrombi with first-generation DES and EES were 234 and 256, respectively.

CONCLUSION: CYP2C19 loss-of-function polymorphism is associated with a higher incidence of intra-stent thrombi after first-generation DES implantation, while the impact is attenuated following EES implantation.