MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2174/0115734056394257250818060804

Медицинская библиотека · Current medical imaging · 2025

Artificial Intelligence-based Liver Volume Measurement Using Preoperative and Postoperative CT Images.

Kim Kwang Gi, Kim Doojin, Lee Chang Hyun, Yeom Jong Chan, Kim Young Jae, Park Yeon Ho, Yang Jaehun

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Accurate liver volumetry is crucial for hepatectomy. In this study, we developed and validated a deep learning system for automated liver volumetry in patients undergoing hepatectomy, both preoperatively and at 7 days and 3 months postoperatively.

METHODS

A 3D U-Net model was trained on CT images from three time points using a five-fold cross-validation approach. Model performance was assessed with standard metrics and comparatively evaluated across the time points.

RESULTS

The model achieved a mean Dice Similarity Coefficient (DSC) of 94.31% (preoperative: 94.91%; 7-day post-operative: 93.45%; 3-month postoperative: 94.57%) and a mean recall of 96.04%. The volumetric difference between predicted and actual volumes was 1.01 ± 0.06% preoperatively, compared to 1.04 ± 0.03% at other time points (p < 0.05).

DISCUSSION: This study demonstrates a novel capability to automatically track post-hepatectomy regeneration using AI, offering significant potential to enhance surgical planning and patient monitoring. A key limitation, however, was that the direct correlation with clinical outcomes was not assessed due to constraints of the current dataset. Therefore, future studies using larger, multi-center datasets are essential to validate the model's clinical and prognostic utility.

CONCLUSION

The developed artificial intelligence model successfully and accurately measured liver volumes across three critical post-hepatectomy time points. These findings support the use of this automated technology as a precise and reliable tool to assist in surgical decision-making and postoperative assessment, providing a strong foundation for enhancing patient care.

Для цитирования: Kim Kwang Gi, Kim Doojin, Lee Chang Hyun, Yeom Jong Chan, Kim Young Jae, Park Yeon Ho, Yang Jaehun. Artificial Intelligence-based Liver Volume Measurement Using Preoperative and Postoperative CT Images.. Current medical imaging. 2025. DOI: 10.2174/0115734056394257250818060804.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.