BACKGROUND

Despite the absence of clinical complications after an acute aortic dissection (AD) with persistent patent false lumen (FL), a high risk for clinical events may persist.

OBJECTIVES

The aim of this study was to assess the natural evolution of noncomplicated AD and ascertain whether different FL flow patterns by magnetic resonance imaging (MRI) have independent prognostic value for AD-related events beyond established morphologic parameters.

METHODS

One hundred thirty-one consecutive patients, 78 with surgically treated type A dissections and 53 with medically treated type B dissections, were followed up prospectively after acute AD with persistent patent FL in the descending aorta. Maximum aortic diameter, true lumen compression, entry tear, and partial FL thrombosis by computed tomography were assessed. Systolic antegrade true lumen and FL flow volumes and diastolic antegrade and retrograde flows were analyzed by MRI during the first year after AD.

RESULTS

After a median follow-up period of 8.0 years (IQR: 4.6-10.9 years), 43 patients presented aorta-related events (25 died and 18 required endovascular treatment). FL systolic antegrade flow ≥30% with respect to total systolic antegrade flow and retrograde diastolic flow ≥80% with respect to total diastolic FL flow were predictors of aortic events. In multivariate analysis, aortic diameter >45 mm (HR: 2.91), type B dissection (HR: 2.44), and MRI flow pattern (HR: 16.87) were independent predictors of AD-related events.

CONCLUSIONS

High systolic antegrade flow volume in the FL with significant diastolic retrograde flow assessed by MRI and aortic diameter >45 mm identify patients with higher risk for complications in whom more aggressive management would be indicated.

Для цитирования: Evangelista Arturo, Pineda Victor, Guala Andrea, Bijnens Bart, Cuellar Hug, Rudenick Paula, Sao-Aviles Augusto, Ruiz Aroa, Teixido-Tura Gisela, Rodriguez-Lecoq Rafael, Bellmunt Sergi, Ferreira Ignacio, Rodríguez-Palomares Jose. False Lumen Flow Assessment by Magnetic Resonance Imaging and Long-Term Outcomes in Uncomplicated Aortic Dissection.. Journal of the American College of Cardiology. 2022. DOI: 10.1016/j.jacc.2022.04.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.