DOI 10.1111/nmo.14227

Медицинская библиотека · Neurogastroenterology and motility · 2021

The effect of an air purifier on aerosol generation measurements during clinical motility testing.

Verbeure Wout, Geeraerts Annelies, Huang I-Hsuan, Timmermans Lien, Tóth Joran, Geysen Hannelore, Cools Louise, Carbone Florencia, Schol Jolien, Devriese Herman, Haesaerts Rico, Mori Hideki, Vanuytsel Tim, Tack Jan

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Aerosol spread is key to interpret the risk of viral contamination during clinical procedures such as esophageal high-resolution manometry (HRM). Installing an air purifier seems a legitimate strategy, but this has recently been questioned.

METHODS

Patients undergoing an HRM procedure at the Leuven University Hospital were included in this clinical study. All subjects had to wear a surgical mask which was only lowered beneath the nose during the placement and removal of the nasogastric catheter. The number of aerosol particles was measured by a Lasair® II Particle Counter to obtain data about different particles sizes: 0.3; 0.5; 1.0; 3.0; 5.0; and 10.0 µm. Measurements were done immediately before the placement and the removal of the HRM catheter, and one and 5 min after. A portable air purifier with high-efficiency particle air filters was installed in the hospital room.

KEY

RESULTS

Thirteen patients underwent a manometry examination. The amount of 0.3 µm-sized particles was unaffected during the whole procedure. The larger particle sizes (1.0; 3.0; 5.0; and 10.0 µm) decreased when the catheter was positioned, but not 0.5 µm. During the HRM measurements itself, these numbers decreased further. Yet, 1 min after catheter removal a significant elevation of particles was seen, which did not recover within 5 min.

CONCLUSIONS & INTERFERENCES: Based on this study, there is no evidence that filtration systems reduce aerosol particles properly during a clinical investigation.

Для цитирования: Verbeure Wout, Geeraerts Annelies, Huang I-Hsuan, Timmermans Lien, Tóth Joran, Geysen Hannelore, Cools Louise, Carbone Florencia, Schol Jolien, Devriese Herman, Haesaerts Rico, Mori Hideki, Vanuytsel Tim, Tack Jan. The effect of an air purifier on aerosol generation measurements during clinical motility testing.. Neurogastroenterology and motility. 2021. DOI: 10.1111/nmo.14227.