MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11517-014-1235-x

Медицинская библиотека · Medical & biological engineering & computing · 2014

The influence of intraluminal thrombus on noninvasive abdominal aortic aneurysm wall distensibility measurement.

Metaxa Eleni, Kontopodis Nikolaos, Vavourakis Vasileios, Tzirakis Konstantinos, Ioannou Christos V, Papaharilaou Yannis

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Abdominal aortic aneurysm wall distensibility can be estimated by measuring pulse pressure and the corresponding sac volume change, which can be obtained by measuring wall displacement. This approach, however, may introduce error if the role of thrombus in assisting the wall in bearing the pulse pressure loading is neglected. Our aim was to introduce a methodology for evaluating and potentially correcting this error in estimating distensibility. Electrocardiogram-gated computed tomography images of eleven patients were obtained, and the volume change between diastole and systole was measured. Using finite element procedures, we determined the equivalent pulse pressure loading that should be applied to the wall of a model where thrombus was digitally removed, to yield the same sac volumetric increase caused by applying the luminal pulse pressure to the model with thrombus. The equivalent instead of the measured pulse pressure was used in the distensibility expression. For a relative volumetric thrombus deposition (V ILT) of 50 %, a 62 % distensibility underestimation resulted when thrombus role was neglected. A strong linear correlation was observed between distensibility underestimation and V ILT. To assess the potential value of noninvasive wall distensibility measurement in rupture risk stratification, the role of thrombus on wall loading should be further investigated.

Для цитирования: Metaxa Eleni, Kontopodis Nikolaos, Vavourakis Vasileios, Tzirakis Konstantinos, Ioannou Christos V, Papaharilaou Yannis. The influence of intraluminal thrombus on noninvasive abdominal aortic aneurysm wall distensibility measurement.. Medical & biological engineering & computing. 2014. DOI: 10.1007/s11517-014-1235-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.