INTRODUCTION

The purpose of this study was to determine the accuracy of the unipolar electrogram for identifying the earliest site of ventricular activation. The earliest site of ventricular activation may be identified with the unipolar electrogram by the absence of an R wave. However, the accuracy of this technique is unknown.

METHODS AND

RESULTS

A single ventricular premature complex was induced mechanically at the tip of an electrode catheter to simulate a ventricular premature depolarization site of origin. Unipolar electrograms were recorded from the right ventricular septum at the tip electrode and at 2, 5, 8, and 11 mm from the electrode tip in 20 patients. No R waves were detected at the ventricular premature depolarization site of origin. R waves were detected in 4 of 20 patients (20%) at 2 mm from the tip electrode and 7 of 20 patients (35%) at 5, 8, and 11 mm from the tip electrode. An R wave was not observed at distances < or = 11 mm from the site of tachycardia origin in 13 of 20 patients (65%).

CONCLUSIONS

While an R wave in the unipolar electrogram can be seen as close as 2 mm from the site of impulse origin, the absence of an R wave as an indicator of the site of impulse origin in the right ventricle is highly inaccurate. Therefore, the absence of an R wave in the unipolar electrogram is unlikely to be an adequate guide for identification of an effective target site for ablation of right ventricular tachycardia.

Для цитирования: Man K C, Daoud E G, Knight B P, Bahu M, Weiss R, Zivin A, Souza S J, Goyal R, Strickberger S A, Morady F. Accuracy of the unipolar electrogram for identification of the site of origin of ventricular activation.. Journal of cardiovascular electrophysiology. 1997. DOI: 10.1111/j.1540-8167.1997.tb00619.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.