MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1259/dmfr.20190049

Медицинская библиотека · Dento maxillo facial radiology · 2019

Software comparison to analyze bone radiomics from high resolution CBCT scans of mandibular condyles.

Bianchi Jonas, Gonçalves João Roberto, Ruellas Antonio Carlos de Oliveira, Vimort Jean-Baptiste, Yatabe Marília, Paniagua Beatriz, Hernandez Pablo, Benavides Erika, Soki Fabiana Naomi, Cevidanes Lucia Helena Soares

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Radiomics refers to the extraction and analysis of advanced quantitative imaging from medical images to diagnose and/or predict diseases. In the dentistry field, the bone data from mandibular condyles could be computationally analyzed using the voxel information provided by high-resolution CBCT scans to increase the diagnostic power of temporomandibular joint (TMJ) conditions. However, such quantitative information demands innovative computational software, algorithm implementation, and validation. Our study's aim was to compare a newly developed BoneTexture application to two-consolidated software with previous applications in the medical field, Ibex and BoneJ, to extract bone morphometric and textural features from mandibular condyles.

METHODS

We used an imaging database of HR-CBCT TMJs scans with an isotropic voxel size of 0.08 mm3 . A single group with 66 distinct mandibular condyles composed the final sample. We calculated 18 variables for bone textural features and 5 for bone morphometric measurements using the Ibex, BoneJ and BoneTexture applications. Spearman correlation and Bland-Altman plot analyses were done to compare the agreement among software.

RESULTS

The results showed a high Spearman correlation among the software applications ( r = 0.7-1), with statistical significance for all variables, except Grey Level Non-Uniformity and Short Run Emphasis. The Bland-Altman vertical axis showed, in general, good agreement between the software applications and the horizontal axis showed a narrow average distribution for Correlation, Long Run Emphasis and Long Run High Grey Level Emphasis.

CONCLUSIONS

Our data showed consistency among the three applications to analyze bone radiomics in high-resolution CBCT. Further studies are necessary to evaluate the applicability of those variables as new bone imaging biomarkers to diagnose bone diseases affecting TMJs.

Для цитирования: Bianchi Jonas, Gonçalves João Roberto, Ruellas Antonio Carlos de Oliveira, Vimort Jean-Baptiste, Yatabe Marília, Paniagua Beatriz, Hernandez Pablo, Benavides Erika, Soki Fabiana Naomi, Cevidanes Lucia Helena Soares. Software comparison to analyze bone radiomics from high resolution CBCT scans of mandibular condyles.. Dento maxillo facial radiology. 2019. DOI: 10.1259/dmfr.20190049.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.