Accuracy of a portable electroneurometer for measuring distal motor latency.

Tanaka Hideki, Hashizume Hiroyuki, McCown Cherie, Senda Masuo, Nishida Keiichiro, Inoue Hajime

Клиническое исследованиеСравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

A facile electromyographic test in the outpatient clinic is needed to evaluate the outcome of screening for carpal tunnel syndrome. The purpose of the current prospective study was to compare the accuracy of Nervepace digital electroneurometer (Nervepace) and Dantec Neuromatic 2000M (Dantec) measurements of a wide range of distal motor latency (DML) of the median nerve.

METHODS

The DML values for 112 of 126 median nerves examined with Nervepace and conventional electromyography, Dantec were statistically analyzed in this prospective study. The 30 hands of 15 clinically healthy adults 20-24 years old served as the reference group. Sixty consecutive patients (96 hands) with idiopathic carpal tunnel syndrome provided a wider range of DML values. All of the patients had standard clinical tests and standard motor (Dantec and Nervepace) and sensory (Dantec) electrodiagostic tests before endoscopic carpal tunnel release.

RESULTS

The DML was measurable in all 30 hands of the reference group, in all 96 hands of the patients by Dantec, but in only 82 hands (52 patients) by Nervepace. Nervepace and Dantec DML values of 6.0 ms or less had high correlation and agreement.

CONCLUSIONS

Correlation and agreement decreased significantly among values greater than 6.0 ms.

Для цитирования: Tanaka Hideki, Hashizume Hiroyuki, McCown Cherie, Senda Masuo, Nishida Keiichiro, Inoue Hajime. Accuracy of a portable electroneurometer for measuring distal motor latency.. Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association. 2005. DOI: 10.1007/s00776-005-0928-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.