Peripheral arterial balloon angioplasty: effect of short versus long balloon inflation times on the morphologic results.

Zorger Niels, Manke Christoph, Lenhart Markus, Finkenzeller Thomas, Djavidani Behrus, Feuerbach Stefan, Link Johann

Клиническое исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the effect of different balloon inflation times on angiographic results in peripheral angioplasty.

MATERIALS AND

METHODS

Seventy-four infrainguinal arteriosclerotic lesions were randomized prospectively to undergo balloon dilation for 30 seconds (group I) or 180 seconds (group II). Each group consisted of 37 patients. Postinterventional angiograms were evaluated by two blinded readers. Dissections were graded as follows: 1 = no dissection; 2 = minor flap; 3 = extensive dissection membrane, not flow limiting; or 4 = flow-limiting flap. The rate of major-grade dissections (grades 3 and 4), residual stenosis (>30%), and further interventions were compared with the two-tailed chi(2) test.

RESULTS

In group I, major dissections were noted in 16 patients (43%) compared with five patients (14%) in group II (P =.009). Residual stenoses were found in 12 patients (32%) in group I compared with five patients (14%) in group II (P =.096). The rate of additional interventions was significantly higher in group I than in group II (20 of 37 vs nine of 37; P =.017).

CONCLUSION

A prolonged inflation time of 180 seconds improves the immediate angioplasty result of infrainguinal lesions compared to a short dilation strategy. Significantly fewer major dissections and a modest reduction of residual stenoses are observed. The requirement of costly and time-consuming further interventions is significantly reduced.

Для цитирования: Zorger Niels, Manke Christoph, Lenhart Markus, Finkenzeller Thomas, Djavidani Behrus, Feuerbach Stefan, Link Johann. Peripheral arterial balloon angioplasty: effect of short versus long balloon inflation times on the morphologic results.. Journal of vascular and interventional radiology : JVIR. 2002. DOI: 10.1016/s1051-0443(07)61736-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.