MedElevator Войти в исследования
← Поиск публикаций

DOI 10.14440/jbm.2025.0109

Медицинская библиотека · Journal of biological methods · 2025

Incorporating ultrafiltration into Protein A membrane chromatography as a strategy to reduce elution volume and buffer consumption.

Yuan Gaoya, Qu Meng, Zhang Xudong, Li Yifeng

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Protein A chromatography is widely used for antibody purification. With conventional packed-bed columns, mass transfer within resin beads is diffusion-limited, entailing long residence time to achieve high binding capacities. Recently, several vendors have introduced Protein A membranes as alternatives to traditional Protein A resins/columns. These membranes feature open pore structures that facilitate the convective transport of protein molecules, enabling high binding capacities within significantly shorter residence time. The use of Protein A membranes can improve throughput, eliminate the need for column packing, and reduce cost. These advantages notwithstanding, Protein A membranes present certain drawbacks. A major limitation is their high dead volume-to-stationary phase ratio, which leads to larger elution volumes compared to their conventional counterparts. This results in significant eluate dilution and increased buffer consumption.

OBJECTIVE

In the current study, we aimed to demonstrate that ultrafiltration (UF), when used in combination with Protein A membrane chromatography, can address these limitations by allowing eluate concentration and buffer reuse.

METHODS

A laboratory model of UF integrated Protein A membrane was set up to test the feasibility and effectiveness of the proposed strategy.

RESULTS

Integrated UF effectively concentrated Protein A membrane eluate to a concentration comparable to that of Protein A column eluate. In addition, reuse of pH-adjusted UF filtrate as elution buffer reduces buffer consumption by 50%.

CONCLUSION

UF integration is an effective solution for addressing the problem of increased elution volume and buffer consumption associated with Protein A membrane.

Для цитирования: Yuan Gaoya, Qu Meng, Zhang Xudong, Li Yifeng. Incorporating ultrafiltration into Protein A membrane chromatography as a strategy to reduce elution volume and buffer consumption.. Journal of biological methods. 2025. DOI: 10.14440/jbm.2025.0109.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.